other
Search
Home Search
  • PD-15-SX
    PD-15-SX
    Ø  No Load power consumption<0.5W Ø  Universal AC input range Ø  Miniature size, high power density, high efficiency, long life and high reliability Ø  Withstand 300VA surge input for 5 sec. Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-20℃~70℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  PCB soldering side with conformal coating Ø  Suitable for critical applications Ø  3 years warranty MODEL PD-15-3.3 PD-15-5 PD-15-12 PD-15-15 PD-15-24 OUTPUT DC Output 3.3V 5V 12V 15V 24V Rated Current 4A 3A 1.3A 1A 0.7A Current Range     Note 1 0~4A 0~3A 0~1.3A 0~1.0A 0~0.7A Ripple and Noise  Note 2 -25~70℃ <50mV <50mV <120mV <120mV <120mV Voltage ADJ.  Range 3.1V-3.5V 4.75V-5.25V 11.4V-12.6V 14.25V-15.75V 22.8V-25.2V Voltage Accuracy ±3% Line Regulation ±1% Load Regulation ±2% Set-up Time <2.0S (120Vac input, Full load); <1.0S (230Vac input, Full load) Hold up Time >10mS(120Vac input, Full load); >20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   90Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) 70% 76% 80% 81% 83% AC Current (max.) 0.7A Inrush Current (Typical) 20A@120Vac   40A@230Vac   Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Load 105%~150% of rated output current, Hiccup mode, auto recovery Over Voltage 105%~150% of rated output voltage, Constant Voltage  Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃;  20%~90%RH  No condensing Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMC Emission Compliance to EN55022,EN55024 ClassB Harmonic Current Compliance to EN61000-3-2,-3 EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024,EN61000-6-2 heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 79×51×28mm Packing 48PCS/CTN, 10.4KGS, 0.03CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. 4.  Powerld offer accessories for Din-35 rail bar. Please contact sales staff for details. We always can deliver high-end quality industrial power supply to our customers on time.Welcome you to contact us for more power supply information and look forward to working with you!
  • ABS-50-X
    ABS-50-X power supply
    Ø  No Load power consumption<0.5W Ø  Universal AC input range(88~264Vac) Ø  High efficiency, long life and high reliability Ø  Withstand 300Vac surge input for 5 sec. Ø  Output protections: OVP/OLP/SCP Ø  Wide operating ambient temp (-25℃~70℃) Ø  Altitude up to5000m Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Suitable for critical applications Ø  2 years warranty MODEL ABS-50-5 ABS-50-12 ABS-50-24 ABS-50-48 OUTPUT DC Output 5V 12V 24V 48 Rated Current 8A 4.2A 2.2A 1.12A CurrentRange    Note 1 0~8A 0~4.2A 0~2.2A 0~1.12A Ripple and Noise  Note 2 0~70℃ <80mV <120mV <200mV <200mV -20℃ <160mV <300mV <300mV <500mV Voltage ADJ. Range 4.75V-5.5V 10.8V-13.2V 21.6V-26.4V 43.2~52.8V Voltage Accuracy ±3.0% ±1.0% ±1.0% ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time ≤1S /230Vac input, Full load) ; ≤2S /120Vac input, Full load) Hold up Time ≥10mS(120Vac input, Full load) ; ≥20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   88Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 230Vac ≥80% ≥84.5% ≥87% ≥88.5% 115Vac ≥78% ≥82.5% ≥85% ≥86.5% AC Current (max.) <1.3 A 2.5A Inrush Current (Typical) ﹤45A@230Vac  Cold start Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA PROTECTION Over Load 8.4~12A 4.41~6.3A 2.31~3.3A 1.155~1.65A Protection type: Constant power, Auto recovery(ABS-50-5,hiccup mode) Over voltage 5.5~7.5V 13.8~18V 27.6~36V 55.2~72V Protection type: Constant voltage, Auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2ndEd; IEC 60950-1:2005(2ndEd) ;EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMC Emission Compliance to EN55022 Class B EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 129×98×38mm Packing 30pcs/CTN, 14.2Kgs/CTN, 0.04cbm Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com We are professional manufacturer engaged in the research, development, production, sale and service of Industrial power supply,We sincerely look forward to cooperating with you and creating the future together!
  • PDF-3000-X-1.5U power supply
    PDF-3000-X-1.5U
    Ø  Universal AC input/ Full range(90~264Vac) Ø  Built-in active PFC function, PF>0.98 Ø  Using ZVS technology to reduce power dissipation Ø  Output protection: OVP/OLP/SCP/OPP/OTP Ø  Built in Fan speed control Ø  Built in AC inrush current limiting circuit(<30A) Ø  Build in constant current limiting circuit Ø  Built in Remote Sense Function, power good signal Ø  N+1 redundancy function Ø  Wide operating ambient temperature (-20℃~55℃), full load Ø  Altitude up to 5000m Ø  All using105℃long life electrolytic capacitors Ø  1.5 U low profile Ø  PCB soldering side with conformal coating        Ø  3 years warranty MODEL PDF-3000-48-1.5U OUTPUT DC Output 48V Rated Current (90~174Vac) 31.25A Rated Current (175~264Vac) 62.5A Ripple and Noise Note 2 -20~55℃ ≤400mV Voltage ADJ.  Range 42~56V Voltage Accuracy ±2% Line Regulation ±0.5% Load Regulation ±2% Set-up Time ≤8S (220Vac input, Full load) Hold up Time ≥5mS (220Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot ≤±2400mV INPUT Voltage Range   90Vac~264Vac Input limit voltage 310Vac for long time, no damage PS Frequency Range 47Hz--63Hz Power Factor(Typical) >0.98/220VAC     Full Load Efficiency ( Typical) @ 220Vac ≥91% AC Current (max.) ≤20A Inrush Current (Typical) ≤30A @220Vac       Cold start Leakage Current Input—output: ≤0.25mA     Input—PG: ≤3.5mA PROTECTION Input Low voltage protection point ≤85 Vac, shut down output Low voltage recovery point ≤88Vac, when input voltage raise up to recovery point, auto recovery, return difference≥5V Over voltage protection point ≥295Vac, shut down output Over voltage recovery point ≥286Vac, when input voltage decline to recovery point, auto recovery, return difference≥5V PROTECTION Output Over Load 66~70A, hiccup mode, auto recovery Over Power 3168~3360W Over Temperature 115℃+5℃(detect on Mosfet temperature);shut down,auto recovery after the temperature goes down to75℃ Over Voltage 58~62V, constant voltage, auto recovery Short Circuit Long-term mode, constant current, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -20℃~55℃;  5%~90%RH  No condensing  full load Storage Temp. & Hum. -40℃~70℃;  5%~95%RH  No condensing SAFETY &EMC    (Note 3) Safety Standards Meet IEC60950/UL60950/TUV EN60950-1 Withstand Voltage Primary-Secondary: 4242Vdc/10mA .Primary-PG:2121KVdc/10mA. Secondary-PG: 500KVdc/10mA. Isolation Resistance 10M ohms EMI Conduction & Radiation Compliance to EN55022, CLASS A, FCC PART 15  CLASS A Harmonic Current Compliance to EN61000-3-2,Class D EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 295*127*63mm Packing TBD Cooling method Fored air cooling (Built-in fan,the fan speed is controlled by load and internal temp.) NOTE 1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com. We focus on your industrial power supply project needs, Offering reliable quality and high cost-effective products is always our top priority. Effective Communication within 24 hours.
  • PD-H35SX power supply
    PD-H35SX
    Ø  No Load power consumption<0.5W Ø  High AC input Ø  Miniature size,high power density,high efficiency,long life and high reliability Ø  Withstand 300VA surge input for 5 sec. Ø  Output protections: OLP/OVP/SCP/OPP Ø  Wide operating ambient temp (-25℃~70℃),100% @50℃、70%@70℃ Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Suitable for critical applications Ø  3 years warranty     SPECIFICATION                                              MODEL PD-H35S12 OUTPUT DC Output   Rated Current 2.6A Current Range      0~2.6A Ripple and Noise  Note 2 -25~70℃   Voltage ADJ.  Range 11.4~12.6V Voltage Accuracy ±2.0% Line Regulation ±1.0% Load Regulation ±2.0% Set-up Time <1.0S (230Vac input, Full load) Hold up Time >20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range     Frequency Range 47Hz~63Hz Efficiency ( Typical) 82% AC Current (max.) 0.7A 2.5A Inrush Current (Typical) <40A@230Vac      Cold start Leakage Current Input—output:<3.5mA     Input—PG:<0.25mA PROTECTION Over Load   Over power 37.8~54W, constant power Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum.   Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards   Withstand Voltage Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022 ClassB; FCC PART15 B EMS Immunity Compliance to EN61000-4-2,4,5,8,11; OTHERS MTBF (MIL-HDBK-217F)   Dimension  (L*W*H) 94.5×51.5×29.5mm Packing 48PCS/CTN, 10.42KGS, 0.03CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. 4. Powerld offer accessories for Din-35 rail bar. Please contact sales staff for details. We are professional manufacturer engaged in the research, development, production, sale and service of Industrial power supply,We sincerely look forward to cooperating with you and creating the future together!
  • PD-H40SX power supply
    PD-H40SX
    Ø  No Load power consumption<0.5W Ø  High AC input range Ø  Miniature size,high power density,high efficiency,long life and high reliability Ø  Withstand 300VAC surge input for 5 sec. Ø  Output protections: OLP/OVP/SCP/OPP Ø  Wide operating ambient temp (-25℃~70℃),100% @50℃、60%@70℃ Ø  Operating altitude up to5000M Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Easy assembling from top side Ø  PCB soldering side with conformal coating Ø  Suitable for critical applications Ø  3 years warranty     SPECIFICATION                                              MODEL PD-H40S12 PD-H40S24 OUTPUT DC Output 12V 24V Rated Current 3.3A 1.7A CurrentRange     0~3.3A 0~1.7A Ripple and Noise   Note 2 0~70℃ <80mV <120mV -25~0℃ <180mV <200mV Voltage ADJ. Range 11.4~13.2V 22.8~26.4V Voltage Accuracy ±3.0% ±3.0% Line Regulation ±0.5% ±0.5% Load Regulation ±1.0% ±1.0% Set-up Time <1S (230Vac input, Full load); Hold up Time >20mS(230Vac input, Full load); Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   176Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 115Vac input 83% 86% 230Vac input 84% 87.5% AC Current (max.) <0.6A(max) Inrush Current (Typical) <50A@264Vac    Cold start Leakage Current Input—output:<3.5mA    Input—PG:<0.25mA PROTECTION Over Load 105%~150% of rated output current, constant power, auto recovery Over power 105%~150% of rated output power,constant power Over Voltage 110%~150% of rated output voltage, Constant Voltage Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022 ClassB / FCC Part15 B EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 101.6×63.5×33mm Packing 60PCS/CTN, 15.18KGS, 0.06CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. 4. Powerld offer accessories for Din-35 rail bar. Please contact sales staff for details. We are professional industrial power supply manufacturer,can offer kinds of industrial power supply and custom service.call us now!
  • PD-50-X Power Supply
    PD-50-X
    Ø  No Load power consumption<0.5W Ø  Universal AC input range (88~264Vac) Ø  Miniature size, high power density, high efficiency, long life and high reliability Ø  Withstand 300VA surge input for 5 sec. Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-25℃~70℃) Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Easy assembling from top side Ø  PCB soldering side with conformal coating Ø  Suitable for critical applications Ø  3 years warranty      SPECIFICATION                                               MODEL PD-50-5 PD-50-12 PD-50-15 PD-50-24 PD-50-48 OUTPUT DC Output 5V 12V 15V 24V 48V Rated Current 8A 4.2A 3.4A 2.2A 1.12A Current Range      0~8A 0~4.2A 0~3.4A 0~2.2A 0~1.12A Ripple and Noise   Note 2 0~70℃ <80mV <120mV <120mV <200mV <200 mV -25-0℃ <80mV <200mV <200mV <300mV <500mV Voltage ADJ.  Range 4.75~5.5V 11.4~13.2V 14.25~15V 22.8~26.4V 45.6~52.8V Voltage Accuracy ±3.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <1.5S (230Vac input, Full load) Hold up Time >50mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   88Vac~264Vac,127~370Vdc Frequency Range 47Hz~63Hz Efficiency ( Typical) 115Vacinput 79% 82.5% 83.5% 85% 86.5% 230Vacinput 80% 84.5% 85.5% 87% 88.5% AC Current (max.) <1.3A Inrush Current (Typical) <45A@230Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA    (input 264Vac, 63Hz) PROTECTION Over Load  8.4~12A 4.41~6.3A 3.57~5.1A 2.31~3.3A 1.155~1.65A Protection type: 5V is hiccup mode, rest are constant power, auto recovery Over Voltage 5.75~7.5V 13.8~18V 17.25~22.5V 27.6~36V 55.2~72V Protection type: constant voltage, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 100M ohms EMC Emission Compliance to EN55022 Class B / FCC Part15 Class B EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 99×82×35mm Packing 40PCS/CTN, 12.8KGS, 0.043CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com. In order to adapt to the needs of the market and users, our industrial power supply products are constantly iterative,please feel free to contact us for more details.
  • PD-50-X-D power supply
    PD-50-X-D
    Ø  No Load power consumption<0.5W Ø  Universal AC input range Ø  Miniature size,high power density,high efficiency,long life and high reliability Ø  Withstand 300VA surge input for 5 sec. Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-25℃~70℃),100% @50℃、70%@70℃ Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Easy assembling from top side Ø  PCB soldering side with conformal coating Ø  Suitable for critical applications Ø  3 years warranty      SPECIFICATION                                               MODEL PD-50-5-D PD-50-12-D PD-50-15-D PD-50-24-DII OUTPUT DC Output 5V 12V 15V 24V Rated Current 8A 4.2A 3.4A 2.2A Current Range      0~8A 0~4.2A 0~3.4A 0~2.2A Ripple and Noise    (-25℃~70℃) Note 2 <80mV <120mV <120mV <200mV Voltage ADJ.  Range 4.75~5.5V 11.4~13.2V 14.25V~15V 22.8V-26.4V Voltage Accuracy ±3.0% ±3.0% ±3.0% ±3.0% Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% Load Regulation ±1.0% ±1.0% ±1.0% ±1.0% Set-up Time <1.5S (230Vac input, Full load) Hold up Time >50mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   90Vac~264Vac,127~370Vdc Frequency Range 47Hz~63Hz Efficiency ( Typical) 80% 84.5% 85.5% 87% AC Current (max.) <1.3A Inrush Current (Typical) <40A@230Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Load 105%~150% of rated output current, constant power Over power 105%~150% of rated output current, constant power Over Voltage 115%~150% of rated output voltage, Constant Voltage Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMC Emission Compliance to EN55022 / FCC PART 15 Class B EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 99×82×35mm Packing 40PCS/CTN, 12.8KGS, 0.043CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com. Welcome OEM, ODM industrial power supply and other needs of the inquiry.Our strong supply chain to ensure we can get niche products with competitive price and good quality.
    A total of

    2

    pages
#

Copyright © 2021 Powerld Enterprises Co.,Ltd.. All Rights Reserved.

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #