other
Search
Home Search
  • LPD-150-X Power Supply
    LPD-150-X
    Ø  Universal AC input (90~264Vac) Ø  No load power consumption < 0.5W Ø  High efficiency, long life and high reliability Ø  Withstand 300Vac surge input for 5s Ø  Output protections: OLP/SCP/OVP/OPP Ø  Wide operating ambient temp (-30℃~70℃) Ø  Altitude up to 5000m Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  1U low profile Ø  3 years warranty SPECIFICATION MODEL LPD-150-12 LPD-150-24 OUTPUT DC Output 12V 24V Rated Current 12.5A 6.25A CurrentRange    Note 1 0~12.5A 0~6.25A Ripple and Noise @25C Note 2 150mV 200mV Voltage ADJ. Range 10.8~13.2V 21.6~26.4V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±0.5% Set-up Time ≤600ms (230/115Vac input, Full load) Hold up Time ≥20mS(230Vac input, Full load)    Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   90~264Vac 120-370VDC FrequencyRange 47Hz~63Hz Efficiency ( Typical) @230Vac 85% 89% AC Current (max.) ≤3A(115Vac) / ≤1.7A(230Vac) Inrush Current (Typical) ≤60A@220Vac  Cold start Leakage Current Input—output:<0.25mA ; Input—PG:<0.75mA  (Input 240Vac, 63Hz) PROTECTION Over Load 120%~180% of rated current, Hiccup mode, auto recovery Over power 120%~180% of rated power, Hiccup mode, auto recovery Over voltage 120%~150% of rated output voltage, constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -30℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards Meet UL60950 / EN60950 Withstand Voltage Primary-Secondary:3.75KVac/10mA .Primary-PG:2.0KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance 100M ohms EMC Emission Compliance to EN55032 Class B/FCC Part15 B EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11 OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 159×97×30mm Packing TBD Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com
    A total of

    1

    pages
#

Copyright © 2021 Powerld Enterprises Co.,Ltd.. All Rights Reserved.

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #