  • PDF-500L-X power supply
    PDF-500L-X
    Ø  Universal AC input(90~264Vac) Ø  Built-in active PFC function, PF>0.95 Ø  High efficiency, long life and high reliability Ø  Output protection: OLP/OVP/OTP/SCP Ø  Wide operating ambient temperature (-30℃~70℃) Ø  150%(750W) peak load capacity Ø  Constant current output Ø  Build in remote ON-OFF control Ø  1 U low profile,40.7mm Ø  High efficiency up to 92% Ø  PCB soldering side with conformal coating Ø  Forces air cooling by DC Fan       Ø  3 years warranty MODEL PDF-500L-24 OUTPUT DC Output 24V Rated Current 21A Ripple and Noise Note 2 0-70℃ ≤240mV -30℃ ≤480mV Voltage ADJ.  Range 23.5~26.5V Voltage Accuracy ±3% Line Regulation ±1% Load Regulation ±2% Set-up Time ≤3S (230Vac input, Full load) Hold up Time ≥10mS /(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   90Vac~264Vac Frequency Range 47Hz--63Hz Power Factor(Typical) PF>0.98/115VAC    PF>0.95/230VAC Efficiency ( Typical) ≥92% at 230Vac, full load AC Current (max.) <8A Inrush Current (Typical) <20A@115Vac  ; <40A@230Vac     Cold start Leakage Current Input—output: ≤0.1mA     Input—PG: ≤0.75mA Standby power consumption <1.5W PROTECTION Over Load ≥25A, ≤31.2A,Constant current limiting for some time(31.2A, last ≥3S) then PS stop working for 7S,after 7S,if the load <=rated current, PS will work normally, auto recovery Over Voltage 29~34V, Constant voltage, auto recovery Over Temperture 95℃+5℃(detect on thermal protector temperature);shut down,auto recovery after the temperature goes down to50℃ Short Circuit Long-term mode, constant current, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -30℃~70℃;  20%~90%RH  No condensing  (refer to derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC    (Note 3) Safety Standards UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVdc;≤10mA. Isolation Resistance 10M ohms EMI Conduction&Radiation Compliance to EN55022, FCC PART 15  CLASS B Harmonic Current Compliance to EN61000-3-2, class D EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Remote control Pls refer to below detailed description PG signal POWER GOOD warning signal, normal: 5+0.3V; abnormal: 0-0.8V Dimension  (L*W*H) 218*116.5*40.7mm Packing 6PCS/CTN, 8.0KGS, 0.04CBM Cooling method Fored air cooling(Built-in DC Fan, controlled by temperature and load) Fan working: temperature controller up to 60±10℃or Output Current >10±1A Fan stop working: temperature controller down to 40±10℃or Output Current<9±1A NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com. We are specializes in the research and production of industrial power supply,will go with you all the way.We sincerely invite you to work with us together.
  • ABS-75-X power supply
    ABS-75-X
    Ø  No Load power consumption<0.5W Ø  Universal AC input range(90~264Vac) Ø  High efficiency, long life and high reliability Ø  Withstand 300Vac surge input for 5 sec. Ø  Output protections: OVP/OLP/SCP Ø  Wide operating ambient temp (-25℃~70℃) Ø  Altitude up to5000m Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Suitable for critical applications Ø  2 years warranty MODEL ABS-75-5 ABS-75-12 ABS-75-24 ABS-75-48 OUTPUT DC Output 5V 12V 24V 48 Rated Current 12A 6A 3.2A 1.62A Current Range     Note 1 0~12A 0~6A 0~3.2A 0~1.62A Ripple and Noise  Note 2 0~70℃ <50mV <80mV <80mV <120mV -20℃ <150mV <200mV <200mV <240mV Voltage ADJ.  Range 4.75V-5.5V 10.8V-13.2V 21.6V-26.4V 43.2~52.8V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time ≤1S /230Vac input, Full load) Hold up Time ≥10mS(120Vac input, Full load) ;  ≥20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   90Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) ≥79% ≥84% ≥86.5% ≥88% AC Current (max.) <2.5 A 2.5A Inrush Current (Typical) ﹤60A@264Vac   Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Load 12.6~18A 6.3~9A 3.36~4.8A 1.701~2.43A Protection type: Constant power, Auto recovery Over voltage 5.5~7.0V 13.2~15.6V 26.4~32.4V 52.8~62.4V Protection type: Constant voltage, Auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃;  20%~90%RH  No condensing Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMC Emission Compliance to EN55022  Class B Harmonic Current Compliance to EN61000-3-2 EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11;heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 160×98.3×38mm Packing 20pcs/CTN, 13.6Kgs/CTN, 0.04cbm Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com. We are professional manufacturer engaged in the research, development, production, sale and service of Industrial power supply,We sincerely look forward to cooperating with you and creating the future together!
  • PDF-3000-X-1.5U power supply
    PDF-3000-X-1.5U
    Ø  Universal AC input/ Full range(90~264Vac) Ø  Built-in active PFC function, PF>0.98 Ø  Using ZVS technology to reduce power dissipation Ø  Output protection: OVP/OLP/SCP/OPP/OTP Ø  Built in Fan speed control Ø  Built in AC inrush current limiting circuit(<30A) Ø  Build in constant current limiting circuit Ø  Built in Remote Sense Function, power good signal Ø  N+1 redundancy function Ø  Wide operating ambient temperature (-20℃~55℃), full load Ø  Altitude up to 5000m Ø  All using105℃long life electrolytic capacitors Ø  1.5 U low profile Ø  PCB soldering side with conformal coating        Ø  3 years warranty MODEL PDF-3000-48-1.5U OUTPUT DC Output 48V Rated Current (90~174Vac) 31.25A Rated Current (175~264Vac) 62.5A Ripple and Noise Note 2 -20~55℃ ≤400mV Voltage ADJ.  Range 42~56V Voltage Accuracy ±2% Line Regulation ±0.5% Load Regulation ±2% Set-up Time ≤8S (220Vac input, Full load) Hold up Time ≥5mS (220Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot ≤±2400mV INPUT Voltage Range   90Vac~264Vac Input limit voltage 310Vac for long time, no damage PS Frequency Range 47Hz--63Hz Power Factor(Typical) >0.98/220VAC     Full Load Efficiency ( Typical) @ 220Vac ≥91% AC Current (max.) ≤20A Inrush Current (Typical) ≤30A @220Vac       Cold start Leakage Current Input—output: ≤0.25mA     Input—PG: ≤3.5mA PROTECTION Input Low voltage protection point ≤85 Vac, shut down output Low voltage recovery point ≤88Vac, when input voltage raise up to recovery point, auto recovery, return difference≥5V Over voltage protection point ≥295Vac, shut down output Over voltage recovery point ≥286Vac, when input voltage decline to recovery point, auto recovery, return difference≥5V PROTECTION Output Over Load 66~70A, hiccup mode, auto recovery Over Power 3168~3360W Over Temperature 115℃+5℃(detect on Mosfet temperature);shut down,auto recovery after the temperature goes down to75℃ Over Voltage 58~62V, constant voltage, auto recovery Short Circuit Long-term mode, constant current, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -20℃~55℃;  5%~90%RH  No condensing  full load Storage Temp. & Hum. -40℃~70℃;  5%~95%RH  No condensing SAFETY &EMC    (Note 3) Safety Standards Meet IEC60950/UL60950/TUV EN60950-1 Withstand Voltage Primary-Secondary: 4242Vdc/10mA .Primary-PG:2121KVdc/10mA. Secondary-PG: 500KVdc/10mA. Isolation Resistance 10M ohms EMI Conduction & Radiation Compliance to EN55022, CLASS A, FCC PART 15  CLASS A Harmonic Current Compliance to EN61000-3-2,Class D EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 295*127*63mm Packing TBD Cooling method Fored air cooling (Built-in fan,the fan speed is controlled by load and internal temp.) NOTE 1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com. We focus on your industrial power supply project needs, Offering reliable quality and high cost-effective products is always our top priority. Effective Communication within 24 hours.
  • PS-60-CX power supply
    PS-60-CX
    Ø  Universal AC input/ Full range (90~264Vac) Ø  High Efficiency, high reliability and long life Ø  Output protections: SCP/OVP/ OLP/OPP Ø  Wide operating ambient temperature (-10℃~65℃) Ø  When 176~264Vac input, free air convection, it is 60W; when 90~175Vac input, 10.5CFM, 60W Ø  When 90~175Vac, free air convection, 45W. Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  2*4 size Ø 2 years warranty     MODEL PS-60-C5 PS-60-C12 PS-60-C15 PS-60-C24 PS-60-C48 OUTPUT DC Output 5.0V 12.0V 15.0V 24.0V 48.0V Rated Current(175~264Vac) 8.0A 5.0A 4.0A 2.5 A 1.25A Ripple and Noise  Note 2 0~65℃ <80mV <120mV <150mV <240mV <300mV -10℃~0℃ <200mV <300mV <360mV <360mV <480mV Voltage ADJ. Range 4.75~5.5V 11.4~13.2V 14.25~16.5V 22.8~26.4V 45.6~52.8V Voltage Accuracy ±2.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time ≤1.0S (230Vac input, Full load) Hold up Time ≥50mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange  Note 3 90Vac~264Vac FrequencyRange 47Hz-63Hz Efficiency(Typical) 230Vac input 80% 83% 84% 85% 86% AC Current (max.) <1.5A Inrush Current (Typical) <30A@120Vac   <60A@230Vac     Cold start Leakage Current Input to Output: <0.25mA; Input to PG: <3.5mA PROTECTION Over Load 10.5~18A 5.25~9A 3.78~6.48A 2.625~4.5A 1.31~2.25A Protection type: Hiccup mode, Auto recovery Over Power 52.5~90W 63~108W 56.7~97.2W 63~108W 63~108W Protection type: Hiccup mode, Auto recovery Over Voltage 5.25~7.5V 12.6~18V 15.75~22.5V 25.2~36V 50.4~72V Protection type: Constant voltage, Auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -10℃~65℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -30℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 4) Safety Standards UL60950-1; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac/10mA; Primary-PG:1.5KVac/10mA;Secondary-PG:0.5KVdc/10mA Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022  Class B EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 101.6×51×29mm Packing 60PCS/CTN, 12KGS, 0.024CBM Cooling method Cooling by free air convection NOTE 1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. We are Industrial power supply manufacturer with competitive price and good quality,which are widely recognized and trusted by users and can meet social needs.
  • PD-H35SX power supply
    PD-H35SX
    Ø  No Load power consumption<0.5W Ø  High AC input Ø  Miniature size,high power density,high efficiency,long life and high reliability Ø  Withstand 300VA surge input for 5 sec. Ø  Output protections: OLP/OVP/SCP/OPP Ø  Wide operating ambient temp (-25℃~70℃),100% @50℃、70%@70℃ Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Suitable for critical applications Ø  3 years warranty     SPECIFICATION                                              MODEL PD-H35S12 OUTPUT DC Output   Rated Current 2.6A Current Range      0~2.6A Ripple and Noise  Note 2 -25~70℃   Voltage ADJ.  Range 11.4~12.6V Voltage Accuracy ±2.0% Line Regulation ±1.0% Load Regulation ±2.0% Set-up Time <1.0S (230Vac input, Full load) Hold up Time >20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range     Frequency Range 47Hz~63Hz Efficiency ( Typical) 82% AC Current (max.) 0.7A 2.5A Inrush Current (Typical) <40A@230Vac      Cold start Leakage Current Input—output:<3.5mA     Input—PG:<0.25mA PROTECTION Over Load   Over power 37.8~54W, constant power Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum.   Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards   Withstand Voltage Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022 ClassB; FCC PART15 B EMS Immunity Compliance to EN61000-4-2,4,5,8,11; OTHERS MTBF (MIL-HDBK-217F)   Dimension  (L*W*H) 94.5×51.5×29.5mm Packing 48PCS/CTN, 10.42KGS, 0.03CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. 4. Powerld offer accessories for Din-35 rail bar. Please contact sales staff for details. We are professional manufacturer engaged in the research, development, production, sale and service of Industrial power supply,We sincerely look forward to cooperating with you and creating the future together!