other
Search
Home Search
  • PDF-350-X power supply
    PDF-350-X
    Ø  Universal AC input (90~264Vac) Ø  Built-in active PFC,PF>0.95 Ø  No load power consumption<5W Ø  Withstand 300Vac surge input Ø  High efficiency up to 90% Ø  Output protection: SCP/OLP/OPP/OVP/OTP Ø  Wide operating ambient temperature (-30~70℃) Ø  Operating altitude up to5000m Ø  PCB soldering side with conformal coating Ø  All using105 ℃long life electrolytic capacitor Ø  100% full load burn-in test Ø  Cooling by free air convection Ø  3 years warranty SPECIFICATION                                                       MODEL PDF-350-12 PDF-350-24 PDF-350-48 OUTPUT DC Output 12V 24V 48V Rated Current 25A 14.6A 7.3A CurrentRange    Note 1 0~25A 0~14.6A 0~7.3A Peak Load 30A(last 60S, 230Vac input) 18A(last 60S, 230Vac input) 9A(last 60S, 230Vac input) Ripple and Noise  Note 2 0~70℃ ≤150mV ≤240mV ≤240mV -30℃ ≤240mV ≤480mV ≤480mV Voltage ADJ. Range 11.6~13.2V 23.5~26.5V 47~52.8V Voltage Accuracy ±3.0% Line Regulation ±1.0% Load Regulation ±2.0% Set-up Time ≤3S (230Vac input, Full load) Hold up Time ≥10mS (230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac FrequencyRange 47Hz--63Hz Power Factor(Typical) PF>0.98/115VAC   PF>0.95/230VAC Efficiency ( Typical) ≥90% (230Vac input, full load) ≥90% (230Vac input, full load) ≥93% (230Vac input, full load) AC Current (max.) <5.0A Inrush Current (Typical) <40A@230Vac  <20A@115Vac  Cold start Stand by power consumption <5W Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA PROTECTION Over Load 26.3~37.5A, constant current 15.33~21.9A, constant current 7.7~11A, constant current Over Power 315~450W, constant current 368~525W, constant current 368~525W, constant current Over Voltage 13.8~16.0V 26.5~36V 50~63V Constant voltage, auto recovery Over Temperature 95℃±5℃(detect on temperature controller) shut down o/p voltage, auto recovery after temperature goes down to50C Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -30℃~70℃; 20%~90%RH No condensing(refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 3) Safety Standards UL60950-1 ;EN60950-1:2006 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 10Mohms EMI Conduction & Radiation Compliance to EN55022,FCC PART 15 Class B Harmonic current Compliance to EN61000-3-2,CLASS D EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 199×99×50mm Packing 12PCS/CTN, 13.5KGS, 0.04CBM Cooling method Free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com
  • PD-20-X power supply
    PD-20-X
    Ø  Universal AC input/ Full range Ø  High Efficiency, and High reliability Ø  Ultra-miniature size, low profile Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temperature (-25℃~70℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  3 years warranty MODEL PD-20-3.3 PD-20-5 PD-20-12 PD-20-15 PD-20-24 PD-20-48 OUTPUT DC Output 3.3V 5V 12V 15V 24V 48V Rated Current 4A 4A 1.67A 1.34A 0.84A 0.42A Current Range     Note 1 0~4A 0~4A 0~1.67A 0~1.34A 0~0.84A 0~0.42A Ripple and Noise  Note 2 0~60℃ <50mV <50mV <50mV <50mV <50mV <100mV -20~0℃ <75mV <75mV <75mV <75mV <75mV <100mV Voltage ADJ.  Range 3.1~3.6V 4.4~5.6V 11.1~13.1V 13.7~16.1V 22.0~25.4V 45.6~50.4V Voltage Accuracy ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% Load Regulation ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% Set-up Time <2.0S (115Vac input, Full load); <1.0S (230Vac input, Full load) Hold up Time >10mS(115Vac input, Full load); >20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   85Vac~264Vac,120Vdc~370Vdc Frequency Range 47Hz~63Hz Efficiency ( Typical) 115Vacinput 69% 76% 79% 80% 80% 80% 230Vacinput 68% 75% 78% 79% 79% 79% AC Current (max.) 0.4A 0.5 0.5A 0.5A 0.5A 0.5A Inrush Current (Typical) Cold start  20A@115Vac    40A@230Vac      Leakage Current Input—output:<0.35mA     Input—PG:<0.75mA PROTECTION Over Load 105%~150% rated output power; Hiccup mode, auto recovery Over Voltage 110%~140% of rated output voltage, Constant Voltage.  Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃;  20%~90%RH  No condensing(refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY & EMC Note 3 Safety Standards UL60950-1; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVa;≤10mA .Primary-PG:1.5KVac;≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100Mohms EMI Conduction&Radiation Compliance to EN55022(CISPR22)ClassB Harmonic Current Compliance to EN61000-3-2,17625.1-2003 EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 89×51×20mm Packing 60PCS/CTN, 7.6KGS, 0.017CBM Cooling method Cooling by free air convection NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.        The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. We are Industrial power supply manufacturer with competitive price and good quality,which are widely recognized and trusted by users and can meet social needs.
  • PS-35-X power supply
    PS-35-X
    Ø  Universal AC input/ Full range (90~264Vac) Ø  High Efficiency, low power consumption Ø  Output protections: SCP/OVP/ OLP/OPP Ø  Wide operating ambient temperature (-20℃~65℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test        Ø 3 years warranty MODEL PS-35-5 PS-35-12 PS-35-24 PS-35-48 OUTPUT DC Output 5V 12.0V 24.0V 48.0V Rated Current 6A 3.0A 1.5 A 0.75A Ripple and Noise  Note 2 0~65℃ ≤80mV <120mV <120mV <120mV -20℃~0℃ ≤150mV <200mV <200mV <200mV Voltage ADJ.  Range 4.75~5.5V 11.4~13.2V 22.8~26.4V 45.6~52.8V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time ≤2.0S @ 115Vac      ≤1.0S @ 230Vac   full load Hold up Time ≥10mS @ 115Vac     ≥20mS @ 230Vac  full load Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   Note 3 90Vac~264Vac, 90Vac input full load Frequency Range 47Hz-63Hz Efficiency ( Typical) 220Vac input ≥78% ≥81% ≥83% ≥86% AC Current (max.) <1.0A Inrush Current (Typical) <23A@115Vac    <45A@230Vac      Cold start Leakage Current Input to Output: ≤ 3.5mA ;  Input to PG: ≤ 0.25mA PROTECTION Over Load 6.3~10.8A 3.15~5.4A 1.58~2.7A 0.78~1.35A Protection type: Hiccup model, Auto recovery Over Voltage 5.75~7.5V 13.8~16.2V 27.6~32.4V 55.2~64.8V Protection type: Constant voltage, Auto recovery Over Power 31.5~54W 37.8~64.8W 37.9~64.8W 37.4~64.8W Protection type: Hiccup model, Auto recovery Shorted Circuit Long-term mode, Auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -20℃~65℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -30℃~85℃;  10%~95%RH  No condensing SAFETY &EMC   (Note 4) Safety Standards UL60950-1; EN60950-1:2006 Withstand Voltage Input-Output:3.0KVac/10mA ; Output-PG: 1.5KVac/10mA;Output-PG: 0.5KVdc/10mA Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022 Class B  FCC PART15B EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (35℃, Full load) Dimension  (L*W*H) 101.6×50.8×24mm Packing 60PCS/CTN, 11KGS, 0.024CBM Cooling method Cooling by free air convection NOTE 1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. We are Industrial power supply manufacturer with competitive price and good quality,which are widely recognized and trusted by users and can meet social needs.
  • PD-H75SX power supply
    PD-H75SX
    Ø  No Load power consumption<0.5W Ø  High AC input Ø  Miniature size,high power density,high efficiency,long life and high reliability Ø  Withstand 300VA surge input for 5 sec. Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-25℃~70℃),100% @50℃、70%@70℃ Ø  Operating altitude up to5000M Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Easy assembling from top side Ø  PCB soldering side with conformal coating Ø  Suitable for critical applications Ø  3 years warranty      SPECIFICATION                                              MODEL PD-H75S24 OUTPUT DC Output 24V Rated Current 3A CurrentRange     0~3A Ripple and Noise note2 0℃~70℃ ≤200mV -25℃~0℃ ≤400mV Voltage ADJ. Range 22.8~26V Voltage Accuracy ±3.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <1.5S (230Vac input, Full load) Hold up Time >50mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   176Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 87% AC Current (max.) <1.3A Inrush Current (Typical) <40A@230Vac     Cold start Leakage Current Input—output:<3.5mA    Input—PG:<0.25mA PROTECTION Over Load 3.15~4.5A, constant power Over power 75.6~108W, constant power Over Voltage 27.6~36V, Constant Voltage Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022 / FCC PART15 ClassB EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 99×82×35mm Packing 40PCS/CTN, 12.8KGS, 0.043CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. 4. Powerld offer accessories for Din-35 rail bar. Please contact sales staff for details. We are professional industrial power supply manufacturer,can offer kinds of industrial power supply and custom service.call us now!
  • PD-H100SX power supply
    PD-H100SX
    Ø  No Load power consumption<0.5W Ø  High AC input Ø  Miniature size,high power density,high efficiency,long life and high reliability Ø  Withstand 300VA surge input for 5 sec. Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-25℃~70℃),100% @50℃、70%@70℃ Ø  Operating altitude up to5000M Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Easy assembling from top side Ø  PCB soldering side with conformal coating Ø  Suitable for critical applications Ø  3 years warranty       SPECIFICATION                                              MODEL PD-H100S24 OUTPUT DC Output 24V Rated Current 4A CurrentRange    Note 1 0~4A Ripple and Noise  Note2 0℃~70℃ 80mV -25℃~0℃ 200 mV Voltage ADJ. Range 22.8~26.4V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <1.0S (230Vac input, Full load) Hold up Time >20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   176Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 86.5% AC Current (max.) <1.5A(max) Inrush Current (Typical) <60A@264Vac    Cold start Leakage Current Input—output:<3.5mA    Input—PG:<0.25mA PROTECTION Over Load 105%~150% of rated output current, constant power Over power 105%~150% of rated output power, constant power Over Voltage 115%~150% of rated output voltage, Constant Voltage Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022 / FCC PART15 ClassB Harmonic Current Compliance to EN61000-3-2,-3 Class A EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 129×98×38mm Packing 30PCS/CTN, 14.2KGS, 0.044CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. 4. Powerld offer accessories for Din-35 rail bar. Please contact sales staff for details.   We are professional industrial power supply manufacturer,can offer kinds of industrial power supply and custom service.call us now!
  • DG-30-SX power supply
    DG-30-SX
    Ø  Universal AC input range(90~264Vac) Ø  High efficiency, long life and high reliability Ø  Output protections: OVP/OLP/SCP Ø  Wide operating ambient temp (-25℃~70℃) Ø  Can be installed on TS-35/7.5 or 35/15 Ø  100% full load burn-in test Ø  PCB with conformal coating Ø  Suitable for critical applications Ø  Cooling by free air convection Ø  3 years warranty SPECIFICATION MODEL DG-30-S12 DG-30-S24 OUTPUT DC Output 12V 24V Rated Current 2.5A 1.25A CurrentRange    Note 1 0~2.5A 0~1.25A Ripple and Noise  Note 2 10~50℃ ≤50mV ≤70mV -25~10℃ ≤100mV ≤140mV Voltage ADJ. Range 12~14V 24~28V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1% Set-up Time <1.5S @230Vac Full load Hold up Time ≥20mS @230Vac Full load Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac, 127VDC-370VDC(input V+ connect L, input V- connect N) FrequencyRange 47Hz~63Hz Efficiency ( Typical) 82% @230Vac input, full load 85% @230Vac input, full load AC Current (max.) <0.8A Inrush Current (Typical) 50A/230Vac  Cold start Leakage Current Input—output:≤0.25mA  Input—PE: ≤3.5mA  (264Vac input, 63Hz) PROTECTION Over Load 3~4.0A, hiccup mode, auto recovery 1.5~2.5A, hiccup mode, auto recovery Over voltage 15.0~16.8V, Constant voltage, auto recovery 28.8~31.2V, Constant voltage, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 5%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL60950, EN60950 Withstand Voltage Primary-Secondary: 3KVac/10mA; Primary-PE: 1.5KVac/10mA; Secondary-PE: 0.5KVac/10mA Isolation Resistance >10Mohms EMC Emission Compliance to EN55022, EN55024 Class B Harmonic Current Compliance to EN61000-3-2,CLASS A EMC Immunity Compliance to EN61000-4-2,3,4,5,6,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) 590,000Hrs (25℃, Full load) Dimension (L*W*H) 103.7*32*97.5mm Packing 36pcs/CTN, 8Kgs/CTN, 0.04cbm Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttps://www.powerld.com. DIN rail power supply is a kind of switching power supply, which can convert unstable input voltage into stable output voltage. We can meet all industry standards of DIN rail power supply. Learn more, follow us, and leave us a message.
  • LPD-100-X Power Supply
    LPD-100-X
    Ø        Universal AC input: 90~ 264Vac Ø        Can bear 300Vac for 5s Ø        No load power consumption<0.5W Ø        High efficiency, long life and high reliability Ø        Output protections: OCP/OVP/SCP Ø        Wide operating ambient temperature (-30℃~70℃) Ø        Altitude up to 5000m Ø        All using 105℃ long life electrolytic capacitors. Ø        100% full load burn-in test Ø        1 U low profile Ø        3 years warranty MODEL LPD-100-5 LPD-100-12 LPD-100-15 LPD-100-24 LPD-100-36 LPD-100-48 OUTPUT DC Output 5V 12V 15V 24V 36V 48V Rated Current 18A 8.5A 7A 4.5A 3A 2.3A Current Range 0~18A 0~8.5A 0~7A 0~4.5A 0~3A 0~2.3A Rated Power 90W 102W 105W 108W 108W 110.4W Ripple and Noise (note1) 120 mV 150mV 150mV 200mV 200mV 200mV Voltage ADJ.  Range 4.5~5.5V 10.8~13.2V 13.5~16.5V 21.6~26.4V 32.4~39.6V 43.2~52.8V Voltage Accuracy ±30% ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time ≤500mS  (230Vac/115Vac, Full load) Hold up Time ≥20mS(230Vac, Full load)  ≥10mS(115Vac, Full load) Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT Voltage Range   Note 3 90Vac~264Vac Frequency Range 47Hz-63Hz Efficiency ( Typical) 230Vac input 86% 87% 88 % 90% 90.5% 91% AC Current (max.) <1.9A@115Vac  <1.2A@230Vac Inrush Current (Typical) <65A@230Vac      Cold start PROTECTION Over Power 110%~180% rated power, hiccup mode, auto recovery Over Current 110%~160% of rated current, hiccup mode, auto recovery Over Voltage 5.75~6.9V 13.8~16.2V 18.75~21.75V 28.8~33.6V 41.4~48.6V 55.2~64.8V Protection type: Constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -30℃~70℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC   (Note 4) Safety Standards UL62368-1, IEC/EN62368-1 Withstand Voltage Primary-Secondary:3..0KVac/10mA.; Primary-PE:1.5KVac/10mA; Secondary-PE:0.5KVdc/10mA . Leakage Current Input—output:<0.25mA     Input—PE:<0.75mA  (@240Vac/63Hz) Isolation Resistance 100M ohms EMI Conduction&Radiation Compliance to EN55032 Class B Harmonic Current Compliance to EN61000-3-2,CLASS A EMS Immunity Compliance to EN61000-4-2,3,4,6,8,11 OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 129*97*30mm Packing 30pcs/CTN Cooling method Cooling by free air flow NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • LPD-350-X Power Supply
    LPD-350-X
    Ø  AC input selectable by switch (115Vac/230Vac) Ø  High efficiency, long life and high reliability Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-25℃~70℃) Ø  Altitude up to 5000m Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  3 years warranty SPECIFICATION MODEL LPD-350-12 LPD-350-24 OUTPUT DC Output 12V 24V Rated Current 29.17A 14.58A Current Range     0~29.17A 0~14.58A Ripple and Noise  Note 2 0~70℃ ≤150mV ≤150mV -25℃ ≤300mV ≤300mV Voltage ADJ. Range 10.2~13.8V 21.6~28.8V Voltage Accuracy ±1.5% ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% ±0.5% Set-up Time ≤2.3S Full load Hold up Time ≥12mS/115Vac input, Full load; ≥16mS/230Vac input, Full load Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT VoltageRange   90Vac~132Vac/180Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency @230Vac input ≥85% ≥87% AC Current (max.) <6.8A/115Vac ; <3.4A/230Vac 2.5A Inrush Current ﹤60A@ 115Vac/230Vac  Cold start Leakage Current Input—output:<0.25mA    Input—PG:<2.0mA (Input 240Vac) PROTECTION Over Load 30.63~43.75A 15.31~21.88A Protection type: Hiccup mode, auto recovery Over Power 367.5~525W 367.5~525W Protection type: Hiccup mode, auto recovery Over voltage 13.8~16.2V 28.8~33.6V Protection type: Constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards GB4943 / EN60950 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:2.0KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance 10M ohms EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 190*99*30mm Packing TBD Cooling method Cooling by forced air (Built-in DC fan) NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com
  • PWF-100L-X Power Supply
    PWF-100L-X
    Ø  Universal AC input range (85~264Vac) Ø  Built-in Active PFC function, PF>0.93 Ø  Miniature size, high power density ,high efficiency, long life and high reliability Ø  Output protections: OLP/SCP/OPP Ø  Wide operating ambient temp (-20℃~65℃) Ø  Operating altitude up to5000M Ø  100% full load burn-in test Ø  Easy assembling from top side Ø  PCB soldering side with conformal coating Ø  Suitable for critical applications Ø  3 years warranty       SPECIFICATION                                              MODEL PWF-100L-12 PWF-100L-24 PWF-100L-36 PWF-100L-48 OUTPUT DC Output 12V 24V 36V 48V Rated Current 8.5A 4.2A 2.75A 2.15A CurrentRange    Note 1 0~8.5A 0~4.2A 0~2.75A 0~2.15A Ripple and Noise  Note 2 0~65℃ ≤100mV ≤150mV ≤250mV ≤250mV -20~0℃ ≤200mV ≤300mV ≤500mV ≤500mV Voltage ADJ. Range ±10% of rated output voltage Voltage Accuracy ±2.0% ±1.0% ±1.0% ±1.0% Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% Load Regulation ±0.5% ±0.5% ±1.0% ±0.5% Set-up Time ≤2S   (230Vac input, full load) Hold up Time ≥20mS (230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   85Vac~264Vac FrequencyRange 47Hz~63Hz Power factor (typical) PF>0.93@230Vac Efficiency (Typical)230Vac input ≥85% ≥86% ≥86% ≥87% Efficiency (Typical)120Vac input ≥83% ≥83% ≥83% ≥84% AC Current (max.) 1.7A/115Vac 0.8A/230Vac Inrush Current (Typical) <50A@230Vac     Cold start Leakage Current Input—output: ≤0.25mA   Input—PG: ≤3.5mA PROTECTION Over Load 105%~200% of rated output current, hiccup mode, auto recovery Over power 105%~200% of rated output current, hiccup mode, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -20℃~65℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -20℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2ndEd; IEC 60950-1:2005(2ndEd) ;EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance 100Mohms EMSEmission Compliance to EN55022, EN55024, FCC PART 15 CLASS B Harmonic Current Compliance to EN61000-3-2, Class D EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 199×99×38mm Packing 20PCS/CTN, 14.5KGS, 0.04CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com Powerld enterprises is specialized in switching power supply since 1991, obtained ISO9001 certificate in 2002, ISO14001 certificate in 2006.As a professional switching power supply manufacturer,Powerld can supply a broad range of power supply,we can not only supply our customers with high quality products,but also our best service and fast delivery time.
    A total of

    3

    pages
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #