  • LPD-100-X Power Supply
    LPD-100-X
    Ø        Universal AC input: 90~ 264Vac Ø        Can bear 300Vac for 5s Ø        No load power consumption<0.5W Ø        High efficiency, long life and high reliability Ø        Output protections: OLP/OVP/SCP Ø        Wide operating ambient temperature (-30℃~70℃) Ø        Altitude up to 5000m Ø        All using 105℃ long life electrolytic capacitors. Ø        100% full load burn-in test Ø        1 U low profile Ø        3 years warranty SPECIFICATION                                                       MODEL LPD-100-5 LPD-100-12 LPD-100-15 LPD-100-24 LPD-100-36 LPD-100-48 OUTPUT DC Output 5V 12V 15V 24V 36V 48V Rated Current 18A 8.5A 7A 4.5A 3A 2.3A Ripple and Noise (note1) 120 mV 150mV 150mV 200mV 200mV 200mV Voltage ADJ. Range -10% ~ +10% of rated voltage Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time ≤500mS (230Vac/115Vac, Full load) Hold up Time ≥20mS(230Vac, Full load) ≥10mS(115Vac, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange  Note 3 90Vac~264Vac FrequencyRange 47Hz-63Hz Efficiency ( Typical) 230Vac input 86% 87% 88 % 90% 90.5% 91% AC Current (max.) <1.9A@115Vac <1.2A@230Vac Inrush Current (Typical) <65A@230Vac     Cold start Standby power <0.5W PROTECTION Over Power 110%~180% rated power, hiccup mode, auto recovery Over Load 110%~180% rated current, hiccup mode, auto recovery Over Voltage 115%~150% rated voltage, constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -30℃~70℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 4) Safety Standards Meet UL60950-1, TUV EN60950-1, EN61558-1/-2-16,CCC GB4943 Withstand Voltage Primary-Secondary:3.75KVac/10mA.; Primary-PE:2.0KVac/10mA; Secondary-PE:0.5KVdc/10mA . Leakage Current Input—output:<0.25mA    Input—PE:<0.75mA (@240Vac/63Hz) Isolation Resistance 100M ohms EMI Conduction&Radiation Compliance to EN55022 Class B / FCC Part15 Class B Harmonic Current Compliance to EN61000-3-2,CLASS A EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11 OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 129×97×30mm Packing TBD Cooling method Cooling by free air flow NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com
    A total of

    1

    pages
#

Copyright © 2021 Powerld Enterprises Co.,Ltd.. All Rights Reserved.

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #