other
Search
Home Search
  • DG-60-SX Din rail power supply
    DG-60-SX
    Ø  Universal AC input range(90~264Vac) Ø  300Vac surge for 3 seconds Ø  High efficiency, long life and high reliability Ø  Output protections: OVP/OLP/SCP Ø  Wide operating ambient temp (-25℃~50℃) Ø  Can be installed on TS-35/7.5 or 35/15 Ø  100% full load burn-in test Ø  PCB with conformal coating Ø  Suitable for critical applications Ø  Cooling by free air convection Ø  3 years warranty SPECIFICATION MODEL DG-60-S12 DG-60-S24 DG-60-S48 OUTPUT DC Output 12V 24V 48V Rated Current 5A 2.5A 1.25A CurrentRange    Note 1 0~5A 0~2.5A 0~1.25A Ripple and Noise  Note 2 10~50℃ ≤60mV ≤50mV ≤120mV -25~10℃ ≤120mV ≤100mV ≤240mV Voltage ADJ. Range 12~14V 24~28V 48~56V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1% Set-up Time <1.5S @230Vac Full load Hold up Time ≥20mS @230Vac Full load Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac, 127VDC-370VDC(input V+ connect L, input V- connect N) FrequencyRange 47Hz~63Hz Efficiency ( Typical) @ 230Vac 86% 88% 89% AC Current (max.) <1.6A Inrush Current (Typical) 65A/230Vac  Cold start 50A/230Vac  Cold start 65A/230Vac  Cold start Leakage Current Input—output:≤0.25mA  Input—PE: ≤3.5mA PROTECTION Over Load 6~7.5A Hiccup mode, auto recovery 3~4A Hiccup mode, auto recovery 1.5~2.5A Hiccup mode, auto recovery Over voltage 15.4~18V Hiccup mode, auto recovery 28.8~31.2V Hiccup mode, auto recovery 58~63V Hiccup mode, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~50℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 5%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL60950, EN60950 Withstand Voltage Primary-Secondary: 3KVac/10mA; Primary-PE: 1.5KVac/10mA; Secondary-PE: 0.5KVac/10mA Isolation Resistance >10Mohms EMC Emission Compliance to EN55022, EN55024 Class B Harmonic Current Compliance to EN61000-3-2,CLASS A EMC Immunity Compliance to EN61000-4-2,3,4,5,6,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) 590,000Hrs (25℃, Full load) Dimension (L*W*H) 103.7*32*97.5mm Packing 36pcs/CTN Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com. We have a complete DIN rail power supply product catalog, providing reliable quality DIN rail power supply and affordable prices, fast delivery, customizable, please leave a message for consultation.
  • PD-50-X Power Supply
    PD-50-X
    Ø  No Load power consumption<0.5W Ø  Universal AC input range (88~264Vac) Ø  Miniature size, high power density, high efficiency, long life and high reliability Ø  Withstand 300VA surge input for 5 sec. Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-25℃~70℃) Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Easy assembling from top side Ø  PCB soldering side with conformal coating Ø  Suitable for critical applications Ø  3 years warranty      MODEL PD-50-5 PD-50-12 PD-50-15 PD-50-24 PD-50-48 OUTPUT DC Output 5V 12V 15V 24V 48V Rated Current 8A 4.2A 3.4A 2.2A 1.12A Current Range      0~8A 0~4.2A 0~3.4A 0~2.2A 0~1.12A Ripple and Noise   Note 2 0~70℃ <80mV <120mV <120mV <200mV <200 mV -25-0℃ <80mV <200mV <200mV <300mV <500mV Voltage ADJ.  Range 4.75~5.5V 11.4~13.2V 14.25~15V 22.8~26.4V 45.6~52.8V Voltage Accuracy ±3.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <1.5S (230Vac input, Full load) Hold up Time >50mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   88Vac~264Vac,127~370Vdc Frequency Range 47Hz~63Hz Efficiency ( Typical) 115Vacinput 79% 82.5% 83.5% 85% 86.5% 230Vacinput 80% 84.5% 85.5% 87% 88.5% AC Current (max.) <1.3A Inrush Current (Typical) <45A@230Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA    (input 264Vac, 63Hz) PROTECTION Over Load  8.4~12A 4.41~6.3A 3.57~5.1A 2.31~3.3A 1.155~1.65A Protection type: 5V is hiccup mode, rest are constant power, auto recovery Over Voltage 5.75~7.5V 13.8~18V 17.25~22.5V 27.6~36V 55.2~72V Protection type: constant voltage, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards UL62368-1 ; IEC62368-1; EN62368-1 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 100M ohms EMC Emission Compliance to EN55032 Class B EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 99×82×35mm Packing 40PCS/CTN, 12.8KGS, 0.043CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • PS-100-X power supply
    PS-100-X
    Ø  High AC input 176~264Vac Ø  High power density,High effiency and reliability Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temperature (-20℃~70℃) Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø 3’’*5’’ compact size Ø  2 years warranty MODEL PS-100-12 PSGZM-H25S8.5 GZM-H25S12II PS-100-24 OUTPUT DC Output 12V 8.5V 12V 24V Rated Current 8.33A 3A 2 A 4.16A CurrentRange   Note 1 0~8.33A 0~3A 0~2A 0~4.16A Ripple and Noise Note 2 0~70C 100mV 120mV -20C~0 120mV 85mV 120mV 120mV Voltage ADJ. Range ±10% of rated output voltage Voltage Accuracy ±1.0% ±3.0% ±5.0% ±2.0% Line Regulation ±0.5% ±0.5% ±1.0% ±0.5% Load Regulation ±1.0% ±2.0% ±1.0% ±1.0% Set-up Time <2.0S (220Vac input, Full load) Hold up Time >10mS(220Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshootand Undershoot <5.0% INPUT VoltageRange   176Vac~264Vac FrequencyRange 47Hz--63Hz Efficiency ( Typical) 83% 85% AC Current (max.) 1.5A 0.5A 2.5A 0.3A 1.5A Inrush Current (Typical) <50A@220Vac    Cold start Leakage Current Input-Output: <0.25mA; Output-PG: <3.5mA PROTECTION Over Current 105%~150% of rated output current, hiccup mode, auto recovery Over Voltage 110%~140% of rated output voltage, hiccup mode, auto recovery Short Circuit Long term mode, Auto recovery ENVIRONMENT OperatingambTemp& Hum -20℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   Note 3 Safety Standards GB4943-2001; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA .Secondary-PG:0.5KVDC;≤10mA . Isolation Resistance 100M ohms EMI Conduction&Radiation Compliance to EN55022(CISPR22)ClassB EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8;ENV50204A, heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 127×76.2×32.5mm Packing 24PCS/CTN, 8.5KGS, 0.02CBM Cooling method Cooling by free air convection NOTE 1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. Focus on the development of Industrial power supply for many years,make efforts to meet customers' requirements and search for long-term cooperation.24 hours online service affiliates you to contact us.
  • DG-75-X din rail power supply
    DG-75-X
    Ø  Universal AC input range(85~264Vac) Ø  Support 1+1 or N+1 redundant system(suggest to use redundancy modules.) Ø  Built-in active PFC,PF>0.95 Ø  High efficiency up to 91% Ø  Built-in current sharing function Ø  Built-in current limiting circuit Ø  Output protections: OVP/OLP/SCP/OTP Ø  Wide operating ambient temp (-25℃~70℃) Ø  150% peak load capacity Ø  Easy Fuse Tripping due to High Overload Current Ø  Excellent Partial Load Efficiency Ø  Built-in DC OK relay contact Ø  Can be installed on TS-35/7.5 or TS-35/15 Ø  100% full load burn-in test Ø  Suitable for critical applications Ø  Ultra-slim, 32mm width Ø  3 years warranty SPECIFICATION                                               MODEL DG-75-12 DG-75-24 DG-75-48 OUTPUT DC Output 12V 24V 48V Rated Current 6.3A  3.2A 1.6A CurrentRange    Note 1 0~6.3A 0~3.2A 0~1.6A Ripple and Noise  Note 2 0~70℃ ≤100mV ≤120mV ≤120mV -25℃ ≤200mV ≤240mV ≤240mV Voltage ADJ. Range 12~14V 24~28V 48~56V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <250mS@230Vac ; <500mS@100Vac Hold up Time ≥20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   85Vac~264Vac, 127Vdc-360Vdc FrequencyRange 47Hz~63Hz Power Factor (typical) 0.99/100Vac    0.95/230Vac Efficiency ( Typical) 88% 91% 91% AC Current (max.) <0.95 A/100Vac       <0.45A/230Vac Inrush Current (Typical) <30A/100Vac     <60A/230Vac  Cold start Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA PROTECTION Over Load 110%~150% of rated current, Constant power limiting for some time(150% of rated current, last 3S) then PS stop working for 7S,after 7S,if the load <=rated current, PS will work normally, auto recovery Over voltage 15~18V 29~33V 58~65V Protection type: Hiccup mode, Auto recovery Over temperature 100±5℃, detect on heat sink of power transistor; shut down O/P, auto recovery after temperature goes down. Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 5%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards meet UL508, UL60950, EN60950 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:2.5KVac;≤10mA. Secondary-PG:0.5KVac≤10mA. Isolation Resistance ≥100M ohms EMC Emission Compliance to EN55022, EN55024, FCC PART 15 Class B Harmonic Current Compliance to EN61000-3-2, CLASS A EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 300,000Hrs (25℃, Full load) Dimension (L*W*H) 124*119*32mm Packing 28pcs/CTN,17.6Kg, 0.04cbm Cooling method Cooling by free air convection Additional function Power boost 150% of rated current DC OK V On: when output voltage is up to 90% of rated output voltage V Off: when output voltage is down to 80% of rated output voltage DC OK relay contact rating Max 30V/1Aor 60V/0.3Aor 30Vac/0.3AResistive load Parallel function support NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com DIN rail power supply is a kind of switching power supply, which can convert unstable input voltage into stable output voltage. We can meet all industry standards of DIN rail power supply. Learn more, follow us, and leave us a message.
  • PD-50-X-D power supply
    PD-50-X-D
    Ø  No Load power consumption<0.5W Ø  Universal AC input range Ø  Miniature size,high power density,high efficiency,long life and high reliability Ø  Withstand 300VA surge input for 5 sec. Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-25℃~70℃),100% @50℃、70%@70℃ Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Easy assembling from top side Ø  PCB soldering side with conformal coating Ø  Suitable for critical applications Ø  3 years warranty      MODEL PD-50-5-D PD-50-12-D PD-50-24-DII OUTPUT DC Output 5V 12V 24V Rated Current 8A 4.2A 2.2A Current Range      0~8A 0~4.2A 0~2.2A Ripple and Noise    (-25℃~70℃) Note 2 <80mV <120mV <200mV Voltage ADJ.  Range 4.75~5.5V 11.4~13.2V 22.8V-26.4V Voltage Accuracy ±3.0% ±3.0% ±3.0% Line Regulation ±0.5% ±0.5% ±0.5% Load Regulation ±1.0% ±1.0% ±1.0% Set-up Time <1.5S (230Vac input, Full load) Hold up Time >50mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   90Vac~264Vac,127~370Vdc Frequency Range 47Hz~63Hz Efficiency ( Typical) 80% 84.5% 87% AC Current (max.) <1.3A Inrush Current (Typical) <40A@230Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Load 105%~150% of rated output current, constant power Over power 105%~150% of rated output current, constant power Over Voltage 115%~150% of rated output voltage, Constant Voltage Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards UL62368-1; IEC62368-1; EN62368-1 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance ≥100M ohms EMC Emission Compliance to EN55032 Class B EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 99×82×35mm Packing 40PCS/CTN, 12.8KGS, 0.043CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
  • PSF-125-X power supply
    PSF-125-X
    Ø  Universal AC input/ Full range Ø  High power density,High effiency and reliability Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temperature (-20℃~70℃) Ø  Build-in remote sense function Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  3 years warranty MODEL PSF-125-5 GZM-H25S8.5 PSF-125-12 GZM-H25S12II PSF-125-15 PSF-125-24 PSF-125-36 PSF-125-48 OUTPUT DC Output 5V 8.5V 12V 12V 15V 24V 36V 48V Rated Current 20A 3A 10.5A 2 A 8.4A 5.2A 3.5A 2.6A CurrentRange   Note 1 0~20A 0~3A 0~10.5A 0~2A 0~8.4A 0~5.2A 0~3.5A 0~2.6A Ripple and Noise Note 2 100mV 85mV 100mV 120mV 100mV 100 mV 120 mV 150 mV Voltage ADJ. Range ±10% of rated output voltage Voltage Accuracy ±2.0% ±3.0% ±2.0% ±5.0% ±2.0% ±2.0% ±2.0% ±2.0% Line Regulation ±0.5% ±0.5% ±0.5% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% Load Regulation ±2.0% ±2.0% ±2.0% ±1.0% ±2.0% ±2.0% ±2.0% ±2.0% Set-up Time <=1200mS (230Vac input, Full load)   <=2500mS (115Vac input, Full load) Hold up Time >=17mS(115/230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshootand Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac,127Vdc~370Vdc FrequencyRange 47Hz--63Hz Power Factor(Typical) PF>0.98/115VAC   PF>0.93/230VAC Efficiency ( Typical) 82%/115Vac 85%/115Vac 85%/115Vac 85%/20Vac 86%/115Vacin 86%/115Vac 84%/230Vac 87%/230Vac 87%/230Vac 87%/230Vac 88%/230Vac 88%/230Vac AC Current (max.) 1.5A 0.5A 2.5A 1.5A 0.3A 1.5A 1.5A 1.5A 1.5A Inrush Current (Typical) 60A@230Vac  30A@115Vac  Cold start Leakage Current <3.5mA PROTECTION Over Current 105%~150% of rated output current, hiccup mode, auto recovery Over Voltage 120%~150% of rated output voltage,hiccup mode Short Circuit Auto recovery ENVIRONMENT OperatingambTemp& Hum -20℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   Note 3 Safety Standards GB4943-2011; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA .Secondary-PG:0.5KVDC;≤10mA . Isolation Resistance 100M ohms EMI Conduction&Radiation Compliance to EN55022(CISPR22)ClassB Harmonic Current Compliance to EN61000-3-2,-3 EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA OTHERS MTBF (MIL-HDBK-217F) More than 100,000Hrs (25℃, Full load) Dimension (L*W*H) 127×76×30.5mm Packing 21PCS/CTN, 8.46KGS, 0.015CBM Cooling method Cooling by free air convection NOTE 1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com Focus on the development of Industrial power supply for many years,make efforts to meet customers' requirements and search for long-term cooperation.24 hours online service affiliates you to contact us.
  • DG-120-X  din rail power supply
    DG-120-X
    Ø  Universal AC input range(85~264Vac) Ø  Support 1+1 or N+1 redundant system(suggest to use redundancy modules.) Ø  Built-in active PFC,PF>0.95 Ø  High efficiency up to 92% Ø  Built-in current sharing function Ø  Built-in current limiting circuit Ø  Output protections: OVP/OLP/SCP/OTP Ø  Wide operating ambient temp (-25℃~70℃) Ø  150%(180W) peak load capacity Ø  Easy Fuse Tripping due to High Overload Current Ø  Excellent Partial Load Efficiency Ø  Built-in DC OK relay contact Ø  Can be installed on TS-35/7.5 or TS-35/15 Ø  100% full load burn-in test Ø  Suitable for critical applications Ø  Ultra-slim,32mm width Ø  3 years warranty SPECIFICATION MODEL DG-120-12 DG-120-24 DG-120-48 OUTPUT DC Output 12V 24V 48V Rated Current 10A(pls refer to derating curve) 5A 2.5A CurrentRange Note  0~10A 0~5A 0~2.5 Ripple and Noise  Note 2 0~70℃ ≤100mV ≤120mV ≤240mV -25℃ ≤200mV ≤240mV ≤240mV Voltage ADJ. Range 12~14V 24~28V 48~56V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <250mS@230Vac ; <500mS@100Vac Hold up Time ≥20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   85Vac~264Vac, 127Vdc-360Vdc FrequencyRange 47Hz~63Hz Power Factor (typical) 0.99/100Vac    0.95/230Vac Efficiency ( Typical) 89.5% 91% 92% AC Current (max.) <1.5 A/100Vac       <0.65A/230Vac Inrush Current (Typical) <30A/100Vac     <60A/230Vac  Cold start Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA PROTECTION Over Load 110%~150% of rated current, Constant current limiting for some time(150% of rated current, last 3S) then PS stop working for 7S,after 7S,if the load <=rated current, PS will work normally, auto recovery Over voltage 15~18V 29~33V 58~65V Protection type: Hiccup mode, Auto recovery Over temperature 100±5℃, detect on heat sink of power transistor; shut down O/P, auto recovery after temperature goes down. Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 5%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards meet UL508, UL60950, EN60950 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:2.5KVac;≤10mA. Secondary-PG:0.5KVac≤10mA. Isolation Resistance 10M ohms EMC Emission Compliance to EN55022, EN55024, FCC PART 15 Class B Harmonic Current Compliance to EN61000-3-2, CLASS A EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 300,000Hrs (25℃, Full load) Dimension (L*W*H) 124*119*32mm Packing 28pcs/CTN,18.02Kgs, 0.04cbm Cooling method Cooling by free air convection Additional function Power boost 150% of rated current DC OK V On: when output voltage is up to 90% of rated output voltage V Off: when output voltage is down to 80% of rated output voltage DC OK relay contact rating Max 30V/1Aor 60V/0.3Aor 30Vac/0.3AResistive load Parallel function support NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com. We have a complete DIN rail power supply product catalog, providing reliable quality DIN rail power supply and affordable prices, fast delivery, customizable, please leave a message for consultation.
  • PSF-200-X power supply
    PSF-200-X
    Ø  Universal AC input/ Full range Ø  Built-in Active PFC function Ø  Withstand 300Vac surge input for 5 sec. Ø  High efficiency up to 90%(typ) Ø  Output protections: OLP/OVP/SCP/OPP Ø  Wide operating ambient temperature (-20℃~70℃) Ø  All using105℃long life electrolytic capacitors. Ø  Free air convection for 150W and 200W with 20.5CFM forced air Ø  100% full load burn-in test Ø 5’’*3’’ compact size Ø  3 years warranty MODEL PSF-200-12 GZM-H25S12II PSF-200-24 PSF-200-27 PSF-200-48 OUTPUT DC Output 12V 8.5V 12V 12V 24V 27V 48V Rated Current 16.6A 3A 10.5A 2 A 8.4A 7.4A 4.167A CurrentRange(convection)    0~12.5A 0~3A 0~10.5A 0~2A 0~6.25A 0~5.5A 0~3.13A CurrentRange(20.5CFM fan) 0~16.6A 0~8.4A 0~7.4A 0~4.167A Ripple and Noise Note 20<Ta≤70℃ 0<Ta≤70℃ 120mVp-p 85mV 100mV 120mV 200 mVp-p 100 mVp-p 120 mVp-p -20≤Ta≤0℃ 200 mVp-p 200 mVp-p 150 mVp-p 240 mVp-p Voltage ADJ. Range ±10% of rated output voltage Voltage Accuracy ±1.0% ±3.0% ±5.0% ±2.0% ±2.0% Line Regulation ±0.5% ±0.5% ±1.0% ±0.5% ±0.5% Load Regulation ±1.0% ±2.0% ±1.0% ±2.0% ±2.0% Set-up Time ≤2S (230VAC input, Full load)& ≤4S (115VAC input, Full load) Hold up Time ≥16mS/150W 10mS/200W(115 / 230VAC IN AT FULL LOAD) Temperature Coefficient ±0.03%/℃ Overshootand Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac,127Vdc~370Vdc FrequencyRange 47Hz--63Hz Power Factor(Typical) PF>0.98/115VAC   PF>0.95/230VAC Efficiency ( Typical) ≥89% ≥89% ≥89% ≥90% AC Current (max.) <3A 2.5A 1.5A 0.3A 1.5A 1.5A 1.5A 1.5A Inrush Current (Typical) <50A@230Vac  <30A@115Vac  Cold start Leakage Current ≤3.5mA PROTECTION Over Current 105%~150% of rated output current, hiccup mode, auto recovery Over Power 105%~150% of rated output current, hiccup mode, auto recovery Over Voltage 125%~150% of rated output voltage, hiccup mode, auto recovery Short Circuit Long-term, Auto recovery ENVIRONMENT OperatingambTemp& Hum -20℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   Note 3 Safety Standards UL60950-1; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA .Secondary-PG:0.5KVDC;≤10mA . Isolation Resistance 100M ohms EMI Conduction&Radiation Compliance to EN55022,EN55024 ClassB Harmonic Current Compliance to EN61000-3-2,-3 EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024,EN61000-6-2heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 128×76.5×34.6mm(5’’*3’’) Packing 21PCS/CTN, 8.46KGS, 0.015CBM Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. We focus on your industrial power supply project needs, Offering reliable quality and high cost-effective products is always our top priority. Effective Communication within 24 hours.
  • DG-240-X power supply
    DG-240-X
    Ø  Universal AC input range(85~264Vac) Ø  Support 1+1 or N+1 redundant system(suggest to use redundancy modules.) Ø  Built-in active PFC,PF>0.95 Ø  High efficiency up to 94% Ø  Built-in current sharing function Ø  Built-in current limiting circuit Ø  Output protections: OVP/OLP/SCP/OTP Ø  Wide operating ambient temp (-25℃~70℃) Ø  150%(360W) peak load capacity Ø  Easy Fuse Tripping due to High Overload Current Ø  Excellent Partial Load Efficiency Ø  Built-in DC OK relay contact Ø  Can be installed on TS-35/7.5 or TS-35/15 Ø  100% full load burn-in test Ø  Suitable for critical applications Ø  Ultra-slim, 45mm width Ø  3 years warranty SPECIFICATION                                                MODEL DG-240-24 ABS-75-12 DG-240-48 OUTPUT DC Output 24V 12V 48V Rated Current 10A 6A 5A Current Range     Note 1 0~10A 0~6A 0~5A Ripple and Noise  Note 2 0~70℃ ≤240mV ≤480mV -25℃ ≤480mV ≤480mV Voltage ADJ.  Range 24~28V 48~56V Voltage Accuracy ±3.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <3S@230Vac  Hold up Time ≥20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   85Vac~264Vac, 127Vdc-375Vdc Frequency Range 47Hz~63Hz Power Factor (typical) 0.99/110Vac     0.95/230Vac Efficiency ( Typical) 94% ≥84% 93% ≥88% AC Current (max.) <3.0 A/100Vac        <1.5A/230Vac Inrush Current (Typical) <20A/110Vac      <40A/230Vac   Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Load 110%~150% of rated current, Constant current limiting for some time(150% of rated current, last 3S) then PS stop working for 7S,after 7S,if the load <=rated current, PS will work normally, auto recovery Over voltage 29~33V, constant voltage, Auto recovery 58~63V, constant voltage, Auto recovery Over temperature 105±5℃, detect on heat sink of power transistor; shut down O/P, auto recovery after temperature goes down. Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃;  20%~90%RH  No condensing Storage Temp. & Hum. -40℃~85℃;  5%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards meet UL508, UL60950, EN60950 Withstand Voltage Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:2.5KVac; ≤10mA. Secondary-PG:0.5KVac≤20mA. Isolation Resistance ≥100M ohms EMC Emission Compliance to EN55022, EN55024, FCC PART 15 Class B Harmonic Current Compliance to EN61000-3-2, CLASS A EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 300,000Hrs (25℃, Full load) Dimension  (L*W*H) 45*124*119mm Packing 24pcs/CTN, 21Kgs/CTN, 0.045cbm Cooling method Cooling by free air convection Additional function Power boost 150% of rated current Parallel function support DC-OK V On: when output voltage is up to 90% of rated output voltage V Off: when output voltage is down to 80% of rated output voltage DC-OK relay contact rating Max 30V/1A or 60V/0.3A or 30Vac/0.3A Resistive load NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #