Brand:
POWERLDItem NO.:
ABS-75-XWattage (W):
75Input:
90~264VacOutput:
5, 12, 24, 48PFC:
NConformal Coating:
NApproval:
NDimension:
160×98.3×38mmØ No Load power consumption<0.5W
Ø Universal AC input range(90~264Vac)
Ø High efficiency, long life and high reliability
Ø Withstand 300Vac surge input for 5 sec.
Ø Output protections: OVP/OLP/SCP
Ø Wide operating ambient temp (-25℃~70℃)
Ø Altitude up to5000m
Ø All using105℃long life electrolytic capacitors.
Ø 100% full load burn-in test
Ø Suitable for critical applications
Ø 2 years warranty
MODEL |
ABS-75-5 |
ABS-75-12 |
ABS-75-24 |
ABS-75-48 |
||
OUTPUT |
DC Output |
5V |
12V |
24V |
48 |
|
Rated Current |
12A |
6A |
3.2A |
1.62A |
||
Current Range Note 1 |
0~12A |
0~6A |
0~3.2A |
0~1.62A |
||
Ripple and Noise Note 2 |
0~70℃ |
<50mV |
<80mV |
<80mV |
<120mV |
|
-20℃ |
<150mV |
<200mV |
<200mV |
<240mV |
||
Voltage ADJ. Range |
4.75V-5.5V |
10.8V-13.2V |
21.6V-26.4V |
43.2~52.8V |
||
Voltage Accuracy |
±1.0% |
|||||
Line Regulation |
±0.5% |
|||||
Load Regulation |
±1.0% |
|||||
Set-up Time |
≤1S /230Vac input, Full load) |
|||||
Hold up Time |
≥10mS(120Vac input, Full load) ; ≥20mS(230Vac input, Full load) |
|||||
Temperature Coefficient |
±0.03%/℃ |
|||||
Overshoot and Undershoot |
<5.0% |
|||||
INPUT |
Voltage Range |
90Vac~264Vac |
||||
Frequency Range |
47Hz~63Hz |
|||||
Efficiency ( Typical) |
≥79% |
≥84% |
≥86.5% |
≥88% |
||
AC Current (max.) |
<2.5 A 2.5A |
|||||
Inrush Current (Typical) |
﹤60A@264Vac Cold start |
|||||
Leakage Current |
Input—output:<0.25mA Input—PG:<3.5mA |
|||||
PROTECTION |
Over Load |
12.6~18A |
6.3~9A |
3.36~4.8A |
1.701~2.43A |
|
Protection type: Constant power, Auto recovery |
||||||
Over voltage |
5.5~7.0V |
13.2~15.6V |
26.4~32.4V |
52.8~62.4V |
||
Protection type: Constant voltage, Auto recovery |
||||||
Shorted Circuit |
Long-term mode, auto recovery |
|||||
ENVIRONMENT |
Operating amb. Temp. & Hum. |
-25℃~70℃; 20%~90%RH No condensing |
||||
Storage Temp. & Hum. |
-40℃~85℃; 10%~95%RH No condensing |
|||||
SAFETY &EMC Note 3 |
Safety Standards |
UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 |
||||
Withstand Voltage |
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. |
|||||
Isolation Resistance |
≥100M ohms |
|||||
EMC Emission |
Compliance to EN55022 Class B |
|||||
Harmonic Current |
Compliance to EN61000-3-2 |
|||||
EMC Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11;heavy industry level |
|||||
OTHERS |
MTBF (MIL-HDBK-217F) |
More than 200,000Hrs (25℃, Full load) |
||||
Dimension (L*W*H) |
160×98.3×38mm |
|||||
Packing |
20pcs/CTN, 13.6Kgs/CTN, 0.04cbm |
|||||
Cooling method |
Cooling by free air convection
|
|||||
NOTE |
1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com. |
We are professional manufacturer engaged in the research, development, production, sale and service of Industrial power supply,We sincerely look forward to cooperating with you and creating the future together!
Previous:
ABS-50-X power supplyNext:
ABS-100-XIf you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Categories
Copyright © 2021 Powerld Enterprises Co.,Ltd.. All Rights Reserved.