  • PS-35-X power supply
    PS-35-X
    Ø  Universal AC input/ Full range (90~264Vac) Ø  High Efficiency, low power consumption Ø  Output protections: SCP/OVP/ OLP/OPP Ø  Wide operating ambient temperature (-20℃~65℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test        Ø 3 years warranty MODEL PS-35-5 PS-35-12 PS-35-24 PS-35-48 OUTPUT DC Output 5V 12.0V 24.0V 48.0V Rated Current 6A 3.0A 1.5 A 0.75A Ripple and Noise  Note 2 0~65℃ ≤80mV <120mV <120mV <120mV -20℃~0℃ ≤150mV <200mV <200mV <200mV Voltage ADJ.  Range 4.75~5.5V 11.4~13.2V 22.8~26.4V 45.6~52.8V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time ≤2.0S @ 115Vac      ≤1.0S @ 230Vac   full load Hold up Time ≥10mS @ 115Vac     ≥20mS @ 230Vac  full load Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   Note 3 90Vac~264Vac, 90Vac input full load Frequency Range 47Hz-63Hz Efficiency ( Typical) 220Vac input ≥78% ≥81% ≥83% ≥86% AC Current (max.) <1.0A Inrush Current (Typical) <23A@115Vac    <45A@230Vac      Cold start Leakage Current Input to Output: ≤ 3.5mA ;  Input to PG: ≤ 0.25mA PROTECTION Over Load 6.3~10.8A 3.15~5.4A 1.58~2.7A 0.78~1.35A Protection type: Hiccup model, Auto recovery Over Voltage 5.75~7.5V 13.8~16.2V 27.6~32.4V 55.2~64.8V Protection type: Constant voltage, Auto recovery Over Power 31.5~54W 37.8~64.8W 37.9~64.8W 37.4~64.8W Protection type: Hiccup model, Auto recovery Shorted Circuit Long-term mode, Auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -20℃~65℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -30℃~85℃;  10%~95%RH  No condensing SAFETY &EMC   (Note 4) Safety Standards UL60950-1; EN60950-1:2006 Withstand Voltage Input-Output:3.0KVac/10mA ; Output-PG: 1.5KVac/10mA;Output-PG: 0.5KVdc/10mA Isolation Resistance ≥100M ohms EMI Conduction&Radiation Compliance to EN55022 Class B  FCC PART15B EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (35℃, Full load) Dimension  (L*W*H) 101.6×50.8×24mm Packing 60PCS/CTN, 11KGS, 0.024CBM Cooling method Cooling by free air convection NOTE 1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. We are Industrial power supply manufacturer with competitive price and good quality,which are widely recognized and trusted by users and can meet social needs.
  • LPD-100-X Power Supply
    LPD-100-X
    Ø        Universal AC input: 90~ 264Vac Ø        Can bear 300Vac for 5s Ø        No load power consumption<0.5W Ø        High efficiency, long life and high reliability Ø        Output protections: OCP/OVP/SCP Ø        Wide operating ambient temperature (-30℃~70℃) Ø        Altitude up to 5000m Ø        All using 105℃ long life electrolytic capacitors. Ø        100% full load burn-in test Ø        1 U low profile Ø        3 years warranty MODEL LPD-100-5 LPD-100-12 LPD-100-15 LPD-100-24 LPD-100-36 LPD-100-48 OUTPUT DC Output 5V 12V 15V 24V 36V 48V Rated Current 18A 8.5A 7A 4.5A 3A 2.3A Current Range 0~18A 0~8.5A 0~7A 0~4.5A 0~3A 0~2.3A Rated Power 90W 102W 105W 108W 108W 110.4W Ripple and Noise (note1) 120 mV 150mV 150mV 200mV 200mV 200mV Voltage ADJ.  Range 4.5~5.5V 10.8~13.2V 13.5~16.5V 21.6~26.4V 32.4~39.6V 43.2~52.8V Voltage Accuracy ±30% ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time ≤500mS  (230Vac/115Vac, Full load) Hold up Time ≥20mS(230Vac, Full load)  ≥10mS(115Vac, Full load) Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT Voltage Range   Note 3 90Vac~264Vac Frequency Range 47Hz-63Hz Efficiency ( Typical) 230Vac input 86% 87% 88 % 90% 90.5% 91% AC Current (max.) <1.9A@115Vac  <1.2A@230Vac Inrush Current (Typical) <65A@230Vac      Cold start PROTECTION Over Power 110%~180% rated power, hiccup mode, auto recovery Over Current 110%~160% of rated current, hiccup mode, auto recovery Over Voltage 5.75~6.9V 13.8~16.2V 18.75~21.75V 28.8~33.6V 41.4~48.6V 55.2~64.8V Protection type: Constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -30℃~70℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC   (Note 4) Safety Standards UL62368-1, IEC/EN62368-1 Withstand Voltage Primary-Secondary:3..0KVac/10mA.; Primary-PE:1.5KVac/10mA; Secondary-PE:0.5KVdc/10mA . Leakage Current Input—output:<0.25mA     Input—PE:<0.75mA  (@240Vac/63Hz) Isolation Resistance 100M ohms EMI Conduction&Radiation Compliance to EN55032 Class B Harmonic Current Compliance to EN61000-3-2,CLASS A EMS Immunity Compliance to EN61000-4-2,3,4,6,8,11 OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 129*97*30mm Packing 30pcs/CTN Cooling method Cooling by free air flow NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.cn.
    A total of

    1

    pages
#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #