ABS-150-X
Ø AC input selectable by switch (115Vac/230Vac) Ø High efficiency, long life and high reliability Ø Output protections: OPP/OLP/SCP Ø Wide operating ambient temp (-20℃~70℃) Ø All using105℃long life electrolytic capacitors. Ø 100% full load burn-in test Ø Suitable for critical applications Ø 3 years warranty SPECIFICATION MODEL ABS-150-5 ABS-150-12 ABS-150-24 ABS-150-48 OUTPUT DC Output 5V 12V 24V 48V Rated Current 24A 12.5A 6.25A 3.15A Current Range Note 1 0~24A 0~8.5A 0~6.25A 0~3.15A Ripple and Noise Note 2 0~70℃ <80mV <120mV <120mV <120mV -20℃ <150mV <200mV <200mV <240mV Voltage ADJ. Range 4.75~5.5V 11.4V-13.2V 22.8~27.6V 45.6~52.8V Voltage Accuracy ±2.0% ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time ≤3S /230Vac input, Full load) Hold up Time ≥20mS(230Vac input, Full load) ≥10mS(120Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range 90Vac~132Vac/176Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) ≥78% ≥84% ≥87% ≥87% AC Current (max.) <4.0 A @ 110Vac <2.0A @ 220Vac 2.5A Inrush Current (Typical) ﹤60A@220Vac Cold start Leakage Current Input—output:<0.25mA Input—PG:<3.5mA PROTECTION Over Load 26.4~36A 13.75~18.75A 6.88~9.38A 3.47~4.73A Hiccup mode Constant power, auto recovery Over power 132~180W 165~225W 165~225W 165~225W Hiccup mode Constant power, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -20℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMC Emission Compliance to EN55022 Class B Harmonic Current Compliance to EN61000-3-2, Class D EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 199×98.3×38mm Packing 20pcs/CNT, 15Kgs/CTN, 0.04cbm Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. We are professional manufacturer engaged in the research, development, production, sale and service of Industrial power supply,We sincerely look forward to cooperating with you and creating the future together!