Brand:
POWERLDItem NO.:
PD-35-X-RSWattage (W):
35Input:
88~264VacOutput:
5, 12, 24, 48PFC:
NConformal Coating:
YApproval:
NDimension:
98x82x35mmØ No Load power consumption<0.5W
Ø Universal AC input range (88~264Vac)
Ø Miniature size, high power density, high efficiency, long life and high reliability
Ø Withstand 300VA surge input for 5 sec.
Ø Output protections: OLP/OVP/SCP/OPP
Ø Wide operating ambient temp (-25℃~70℃),100% @50℃、70%@70℃
Ø Operating altitude up to5000M
Ø All using105℃long life electrolytic capacitors.
Ø 100% full load burn-in test
Ø Easy assembling from top side
Ø Suitable for critical applications
Ø 3 years warranty
MODEL |
PD-35-5-RS |
PD-35-12-RS |
PD-35-24-RS |
PD-35-48-RS |
||
OUTPUT |
DC Output |
5V |
12V |
24V |
48V |
|
Rated Current |
6A |
3A |
1.5A |
0.76A |
||
Current Range |
0~6A |
0~3A |
0~1.5A |
0~0.76A |
||
Ripple and Noise Note 2 |
0~70℃ |
<50mV |
<80mV |
<120mV |
<180 mV |
|
-25~0℃ |
<80mV |
<180mV |
<200mV |
<240mV |
||
Voltage ADJ. Range |
4.75~5.5V |
11.4~13.2V |
22.8~26.4V |
45.6~52.8V |
||
Voltage Accuracy |
±3.0% |
|||||
Line Regulation |
±0.5% |
|||||
Load Regulation |
±1.0% |
|||||
Set-up Time |
<1S (230Vac input, Full load); |
|||||
Hold up Time |
>20mS(230Vac input, Full load); >10mS(120Vac input, Full load) |
|||||
Temperature Coefficient |
±0.03%/℃ |
|||||
Overshoot and Undershoot |
<5.0% |
|||||
INPUT |
Voltage Range |
88Vac~264Vac |
||||
Frequency Range |
47Hz~63Hz |
|||||
Efficiency ( Typical) |
78% 220Vac input |
81% 220Vac input |
85% 220Vac input |
85% 220Vac input |
||
AC Current (max.) |
<1A(max) |
|||||
Inrush Current (Typical) |
<50A@264Vac Cold start |
|||||
Leakage Current |
Input—output:<3.5mA Input—PG:<0.25mA |
|||||
PROTECTION |
Over Load |
6.3~9A |
3.15~4.5A |
1.575~2.25A |
0.798~1.14A |
|
Protection type: Constant power, auto recovery |
||||||
Over Voltage |
5.5~7.5V |
13.2~18V |
26.4~36V |
52.8~71V |
||
Protection type: Constant voltage, auto recovery |
||||||
Over Power |
31.5~45W |
37.8~54W |
37.8~54W |
37.8~54W |
||
Protection type: Constant power, auto recovery |
||||||
Short Circuit |
Long-term mode, auto recovery |
|||||
ENVIRONMENT |
Operating amb. Temp. & Hum. |
-25℃~70℃; 20%~90%RH No condensing (refer to the derating curve) |
||||
Storage Temp. & Hum. |
-40℃~85℃; 10%~95%RH No condensing |
|||||
SAFETY &EMC Note 3 |
Safety Standards |
UL60950-1; IEC 60950-1:2005 ;EN60950-1:2006 |
||||
Withstand Voltage |
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. |
|||||
Isolation Resistance |
≥100M ohms |
|||||
EMC Emission |
Compliance to EN55022,EN55024 Class B |
|||||
Harmonic Current |
Compliance to EN61000-3-2,-3 |
|||||
EMC Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level |
|||||
OTHERS |
MTBF (MIL-HDBK-217F) |
More than 200,000Hrs (25℃, Full load) |
||||
Dimension (L*W*H) |
99×82×35mm |
|||||
Packing |
40PCS/CTN, 12.4KGS, 0.04CBM |
|||||
Cooling method |
Cooling by free air convection
|
|||||
NOTE |
1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. |
Our industrial power supply products enjoy great popularity among customers for our good quality and competitive price.We also welcome OEM and ODM orders.
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Categories
Copyright © 2021 Powerld Enterprises Co.,Ltd.. All Rights Reserved.
IPv6 network supported