  • VAT-UP200-X-P-A power supply
    VAT-UP200-X-P-A
    Ø  Universal AC input (90~264Vac) Ø  With Active PFC, PF>0.95 Ø  Surge 300Vac for 60S Ø  High Efficiency, long life and High reliability Ø  Output protections: OLP/OVP/SCP/OPP Ø  1+1 parallel function, current sharing Ø  Wide operating ambient temperature (-40℃~65℃) Ø  Operating altitude up to5000m Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Fanless, quiet working Ø  PCB with conformal coating Ø  Low profile, 30mm Ø  3 years warranty MODEL VAT-UP200-4.2-P-A VAT-UP200-5-P-A OUTPUT DC Output 4.2V 5V Rated Current 40A 40A CurrentRange    Note 1 0~40A 0~40A Peak load 50A(50mS, 220Vac input) Ripple and Noise  Note 2 0~65℃ ≤150MV ≤200MV Voltage Accuracy@-40~65C 4.15~4.4V ±3% Line Regulation/ ±0.5% Load Regulation ±2% Set-up Time @25℃ ≤2S (220Vac input,40A) Hold up Time ≥5mS (220Vac input,32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% Parallel (current sharing) Current-unbalance< 10% (single PS drive40Aload, the voltage of current share bus is 2.9~4V) INPUT VoltageRange  Note 3 90Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 86% (220Vac input,40A) 88% (220Vac input,40A) AC Current (max.) <3.5A Inrush Current (Typical) <60A@220Vac     Cold start Power Factor @25℃ >0.95 (input 220Vac,40A) Stand by power consumption <4W (input 220Vac) Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA  (input 264Vac, 63Hz) PROTECTION Over Load 44~65A, hiccup mode, auto recovery 44~65A, hiccup mode, auto recovery Over Power 184.8~252W, hiccup mode, auto recovery 220~325W, hiccup mode, auto recovery Over Voltage 4.5~6.5V, hiccup mode, auto recovery 5.2~6.5V, constant voltage Over Temperature 105℃+5℃(detect on temperature controller);shut down, auto recovery after the temperature goes down to65℃ Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~65℃; 20%~90%RH No condensing(refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 4) Safety Standards UL60950-1 2ndEd; IEC 60950-1:2005(2ndEd) ;EN60950-1:2006 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 10Mohms EMI Conduction&Radiation Compliance to EN55022  CLASS B EMSImmunity Compliance toEN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) >200000h (25℃, Full load) Dimension (L*W*H) 133*55*30mm Packing 49PCS/CTN, 15KGS, 0.04CBM Power Good Signal Working properly, port voltage: 3.0~3.5V(output current 0~1mA) Working abnormally, port voltage: 0~0.7V(pull-up resistor > 10K) Cooling method Cooling by free air convection NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttps://www.powerld.com. We provide high-quality LED power supplies for indoor and outdoor, and a variety of specifications and models of LED power supplies are optional, suitable for specific lighting applications in multiple fields.
  • VAT-UP400S-X-60L-A power supply
    VAT-UP400S-X-60L-A
    l  AC input: 90-264Vac l   Built-in Active PFC, PF>0.93 l   Output protections: OLP/SCP/OTP/OPP l   Wide operating ambient temperature  (-40℃~80℃) l   No fan suitable for quiet environment l   100% full load burn-in test l   Long life and high reliability l   High efficiency up to 90% l   Conformal coating l   Low profile, 30mm l   3 years warranty MODEL VAT-UP400S-5-60L-A OUTPUT DC Output 5V Output Pre set voltage 5.0-5.10V (220Vac input, load 0A) Rated Current 80A CurrentRange    Note 1 0~80A Peak load 90A, last 50mS @ 220Vac Ripple and Noise 25~80℃ ≤150mV Voltage Adj. Range 4.15~5.10V Voltage Accuracy ±2.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2.5S (110Vac input, Full load), ≤1S (220Vac input, Full load) Hold up Time ≥10mS(220Vac input, 80% load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5% INPUT VoltageRange 90Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 90%(220Vac input ,full load) AC Current (max.) <5A Inrush Current (Typical) <80A@220Vac     Cold start Power factor >0.93(220Vac input ,full load);  >0.95/(110Vac input ,full load) PROTECTION Over Power 425W~550W, Hiccup mode, auto recovery Over Current 85A~110A, Hiccup mode, auto recovery Shorted Circuit Long-term mode, auto recovery Over Temperature 105℃+5℃(detect on Q1/D1 batten);shut down, auto recovery after the temperature goes down ENVIRONMENT Operating amb. Temp. & Hum. -40℃~80℃; 20%~90%RH No condensing  (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards GB4943-2001; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Leakage Current Input—output: ≤0.25mA    Input—PG: ≤3.5mA (264Vac input,63Hz) Isolation Resistance 10Mohms EMI Conduction & Radiation EN55022, EN55024, FCC Part 15, Class B Harmonic Current EN61000-3-2 CLASS D EMSImmunity EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) >200,000Hrs,full load Dimension (L*W*H) 235*60*30mm Packing 18pcs/CTN Cooling method Free air flow (Fixed to aluminum heatshink of customer’s system) NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 100uF parallel capacitor. 3. The SPS is considered a component which will be installed into final equipment. We cannot guarantee that the final equipment will meet EMC directives, Final product manufactures must be re-confirm that their product meets EMC directives. We provide high-quality LED power supplies for indoor and outdoor, and a variety of specifications and models of LED power supplies are optional, suitable for specific lighting applications in multiple fields.
  • VAT-UP400S-X-60L-P
    VAT-UP400S-X-60L-P
    l  AC input: 90VAC ~ 264VAC l  Built-in Active PFC, PF>0.95  l  High efficiency, long life and high reliability l  Output protections: OLP/SCP/OTP l  Wide operating ambient temperature  (-40℃~80℃) l  No fan suitable for quiet environment l  100% full load burn-in test l  1+1 and redundancy, current sharing function l  Conformal coating l  3 years warranty MODEL VAT-UP400S-5-60L-P OUTPUT DC Output 5V Output Pre set voltage 5.0-5.10V (220Vac input, load 0A) Rated Current 80A  ( PSU fixed on heat sink of square > 400*400*2mm aluminum plate) CurrentRange    Note 1 0~80A Ripple and Noise 25~80℃ ≤150mV 0-25C ≤200mV Voltage Adj. Range 4.15~5.10V Voltage Accuracy ±2.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2.5S (110VAC input, Full load) Hold up Time ≥8mS(220Vac input, 80% load) Temperature Coefficient ±0.03%/℃ Current sharing unbalance <10% (Current sharing bus voltage is 2.9-4V, single PS at 80A load) ) Overshoot and Undershoot <5% INPUT VoltageRange 90Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 88%(220Vac input ,full load) AC Current (max.) <5A Inrush Current (Typical) <80A@220Vac     Cold start Power factor >0.93(220Vac input ,full load);  >0.95/(110Vac input ,full load) PROTECTION Over Power 425W~550W, Hiccup, auto recovery Over Current 85A~110A, Hiccup, auto recovery Shorted Circuit Long-term mode, auto recovery Over Temperature 105℃+5℃(detect on Q1/D1 batten);shut down, auto recovery after the temperature goes down ENVIRONMENT Operating amb. Temp. & Hum. -40℃~80℃; 20%~90%RH No condensing  (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Leakage Current Input—output: ≤0.25mA    Input—PG: ≤3.5mA (264Vac input, 63Hz) Isolation Resistance 10Mohms EMI Conduction & Radiation Compliance to EN55022, EN55024, FCC PART 15  CLASS B Harmonic Current Compliance to EN61000-3-2 CLASS D EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 250*60*30mm Packing TBD Cooling method Free air convection PG SIGNAL Power indicator terminal voltage 1.       Power supply is normal, the signal voltage: 3.0V ~ 3.5V (current 0~1mA) 2.       Power supply is abnormal, the signal voltage: 0V ~ 0.7V, (pull-up resistor is greater than 10kΩ) 3.       Control card to detect POWER GOOD signal port, in order to prevent interference misoperation, Recommended MCU or FPGA detection port to add the 0.01uF decoupling capacitor. NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 100uF parallel capacitor. 3. he SPS is considered a component which will be installed into final equipment. We cannot guarantee that the final equipment will meet EMC directives, Final product manufactures must be re-confirm that their product meets EMC directives.
  • VAT260UPXAA
    VAT260UPXAA
    Ø  Universal AC input (90~264Vac) Ø  With Active PFC, PF>0.95 Ø  Stand-by power consumption: 0.35W Ø  High Efficiency, long life and High reliability Ø  Output protections: OCP/OVP/SCP/OTP Ø  Wide operating ambient temperature (-30℃~65℃) Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Fanless, quiet working Ø  PCB with conformal coating Ø  Low profile, 23mm Ø  3 years warranty    Ø  UL/CE/CCC/CB approved MODEL VAT260UP4.2AA VAT260UP5AA OUTPUT DC Output 4.2V 5V Rated Current 50A 50A CurrentRange    Note 1 0~50A 0~50A Ripple and Noise  Note 2 0~65℃ ≤250mV ≤300mV -30~0℃ ≤500mV ≤600mV Voltage Accuracy ±3% Set-up Time @25℃ ≤4S (220Vac input, 50A) Temperature Coefficient ±0.03%/℃ Overshoot ≤5.0% INPUT Voltage Range 90Vac~264Vac Rated input voltage range 100~240Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 90% @220Vac input, 50A ( 91% @220Vac, 60% load) AC Current (max.) <3.5A Inrush Current (Typical) <80A@220Vac     Cold start Power Factor @25℃ >0.95 (input 220Vac, 50A) Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA  (input 264Vac, 63Hz) Input Protection Under voltage protection point 55Vac~85Vac, shut down Under voltage recovery point 60Vac-90Vac, auto recovery, return difference≥5V Output PROTECTION Over Current ≥55A , auto recovery Over Voltage 4.6~6.5V, auto recovery 5.5~7V, auto recovery Over Temperature Test at40A Ambient temp. Protection when ambient temp. is over 65℃; auto recovery when ambient temp. is lower than 50℃ Housing temp. Protection when temp. of upper housing is over 85℃; auto recovery when it is less than 70℃ Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -30℃~65℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 4) Safety Standards IEC 62368-1, UL62368-1, EN62368-1 approved Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVdc/10mA. Isolation Resistance 10Mohms EMI Conduction & Radiation Compliance to EN55032  Class A EMSImmunity Compliance toEN61000-4-2,4,5,11; OTHERS MTBF >100000Hrs (25℃, Full load),MIL-217 Method 2 Components Stress Method Dimension (L*W*H) 165*55*23mm Packing 24pcs/CTN, 9.2Kgs/CTN Cooling method Power supply fixed on the aluminum plate of 450*450*3mm. NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttp://www.powerld.com.cn.
  • VAT-UP200S-X-P
    VAT-UP200S-X-P
    Ø  Universal AC input (90~264Vac) Ø  With Active PFC, PF>0.95 Ø  Surge 300Vac for 60S Ø  High Efficiency, long life and High reliability Ø  Output protections: OLP/OVP/SCP/OTP/OPP Ø  1+1 parallel function, current sharing Ø  Wide operating ambient temperature (-40℃~65℃) Ø  Operating altitude up to5000m Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Fanless, quiet working Ø  PCB with conformal coating        Ø  3 years warranty MODEL VAT-UP200S-4.6-P VAT-UP200S-5-P OUTPUT DC Output 4.6V 5V Rated Current 40A 40A CurrentRange    Note 1 0~40A 0~40A Peak load 50A(50mS, 220Vac input) 48A(50mS, 220Vac input) Ripple and Noise  Note 2 0~65℃ ≤150mV ≤150mV Voltage Accuracy@-20~65C ±3% ±3% Line Regulation/ ±0.5% Load Regulation ±2% Set-up Time @25℃ ≤2S (220Vac input,40A) Hold up Time ≥5mS (220Vac input,32A) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% Parallel (current sharing) Current-unbalance< 10% (single PS drive40Aload, the voltage of current share bus is 5~6V) INPUT VoltageRange  Note 3 90Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency ( Typical) 110Vac 87% 89% 220Vac 88% 90% AC Current (max.) <3.5A Inrush Current (Typical) <15A@220Vac     Cold start Power Factor @25℃ >0.95 (input 220Vac,40A) Stand by power consumption <4W (input 220Vac) Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA  (input 264Vac, 63Hz) PROTECTION Over Load 44~65A, hiccup mode, auto recovery 45~55A, hiccup mode, auto recovery Over Power 193~299W, hiccup mode, auto recovery 225~275W, hiccup mode, auto recovery Over Voltage 5.1~7V, hiccup mode, auto recovery 5.2~6.5V, hiccup mode, auto recovery Over Temperature 105℃+10℃(detect on temperature controller of PFC);shut down, auto recovery after the temperature goes down to75℃ Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~65℃; 20%~90%RH No condensing(refer to the derating curve) Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   (Note 4) Safety Standards UL60950-1 2ndEd; IEC 60950-1:2005(2ndEd) ;EN60950-1:2006 Withstand Voltage Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA. Isolation Resistance 10Mohms EMI Conduction&Radiation Compliance to EN55022, EN55024, FCC PART 15 CLASS B Harmonic current Compliance toEN61000-3-2CLASSD EMSImmunity Compliance toEN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) >200000h (25℃, Full load) Dimension (L*W*H) 210*50*29mm Packing 28PCS/CTN, 0.04CBM Power Good Signal Working properly: 3.3V Working abnormally: <0.7V Reverse voltage start 4.6V output When output reverse voltage is 5~5.1V, PS starts normally. 5V output When output reverse voltage is 5~10V, PS starts normally. Cooling method Cooling by free air convection NOTE 1.    All parameters NOT specially mentioned are measured at rated input, rated load and 25℃of ambient temperature. 2.    Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttp://www.powerld.com.cn.
  • VAT-H300S-X-60L
    VAT-H300S-X-60L
    Ø  High AC input (180-264Vac) Ø  Long life and High reliability Ø  High efficiency up to 89% Ø  Output protections: SCP/OPP/OLP Ø  Wide operating ambient temperature (-40℃~65℃) Ø  @-40C, PS can work normally Ø  Altitude up to 5000m Ø  PCB with conformal coating Ø  100% full load burn-in test Ø  2 years warranty MODEL VAT-H300S-5-60L OUTPUT DC Output 5V Rated Current 60A Current Range     Note 1 0~60A Peak load 65A, last 100mS /220Vac Ripple and Noise  Note 2 25~65℃ ≤150mV 0~25℃ ≤200mV Voltage ADJ.  Range 4.15~5.08V Voltage Accuracy ±2.0% Line Regulation ±0.5% Load Regulation ±2.0% Set-up Time ≤2S (220VAC input, Full load) Hold up Time ≥10mS (220VAC input, 80% load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   180Vac~264Vac Frequency Range 47Hz~63Hz Efficiency ( Typical) 89%(220Vac input, full load) AC Current (max.) <3.5A Inrush Current (Typical) <100A@220Vac      Cold start Leakage Current Input—output:<0.25mA     Input—PG:<3.5mA PROTECTION Over Power 315~450W, hiccup mode, auto recovery Over Current 63~90A, hiccup mode, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~65℃;  20%~90%RH  No condensing Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards GB4943/ EN60950 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance 10M ohms EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11 OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 208*60*30mm Packing TBD Cooling method Free air convection NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.  The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.