Your present location:HomeProductsLED Display Power Supply / VAT-UP200S-5-60L-AII
  • Product No.: VAT-UP200S-5-60L-AII

AC input: 90VAC ~ 264Vac

Built-in Active PFC, PF>0.95

High efficiency, long life and high reliability

Output protections: OLP/SCP

No fan suitable for quiet environment

Wide operating ambient temperature  (-40℃~65℃)

100% full load burn-in test

Conformal coating

3 years warranty

 

MODEL

VAT-UP200S-5-60L-AII

OUTPUT

DC Output

5V

Output Pre set voltage

4.95-5.05V  (220Vac input, load 0A)

Rated Current

40A   ( PSU bottom fixed on heat sink of square > 250*250*2mm aluminum plate)

CurrentRange     Note 1

0~40A

Ripple and Noise

25~65℃

≤150mV

0~25C

≤200mV

Voltage Adj. Range

4.15~5.10V

Voltage Accuracy

±2.0%

Line Regulation

±0.5%

Load Regulation

±2.0%

Set-up Time

≤1.0S (220Vac input, Full load)  &  ≤2.5S (110VAC input, Full load)

Hold up Time

≥10mS(220Vac input , 80% load)

Temperature Coefficient

±0.03%/℃

Overshoot and Undershoot

<5%

INPUT

VoltageRange

90Vac~264Vac

FrequencyRange

47Hz~63Hz

Efficiency ( Typical)

89%(220Vac input ,full load)

AC Current (max.)

<2.5A

Inrush Current (Typical)

<80A@220Vac      Cold start

Power factor

PF>0.95/110VAC    &    PF>0.93/220VAC   (at full load)

PROTECTION

Over Power

225W~300W, Hiccup, auto recovery

Over Current

45A~60A, auto recovery

Shorted Circuit

Long-term mode, auto recovery

ENVIRONMENT

Operating amb. Temp. & Hum.

-40~65;  20%~90%RH  No condensing   (refer to the derating curve)

Storage Temp. & Hum.

-40~85;  10%~95%RH  No condensing

SAFETY &EMC

Note 3

Safety Standards

UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006

Withstand Voltage

Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA.

Leakage Current

Input—output: ≤0.25mA     Input—PG: ≤3.5mA  264Vac input,

Isolation Resistance

10Mohms

EMI Conduction & Radiation

Compliance to EN55022, EN55024, FCC PART 15   CLASS B

Harmonic Current

Compliance to EN61000-3-2  CLASS D

EMSImmunity

Compliance to EN61000-4-2,3,4,5,6,8,11;

OTHERS

MTBF (MIL-HDBK-217F)

More than 200,000Hrs (25C, full load)

Dimension  (L*W*H)

208*60*30mm

Packing

TBD

Cooling method

Free air convection

NOTE

1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃of ambient temperature.

2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 100uF parallel capacitor.

3.  he SPS is considered a component which will be installed into final equipment. We cannot guarantee that the final equipment will meet EMC directives, Final product manufactures must be re-confirm that their product meets EMC directives.