Your present location:HomeProductsLED Display Power Supply / VAT-UP300S-X-60L-A Series
  • Product No.: VAT-UP300S-X-60L-A

AC input: 90 ~ 264Vac

Built-in active PFC function, PF>0.95

High efficiency, long life and high reliability

Output protections: OCP/SCP /OTP

Wide operating ambient temperature(-40℃~65℃)

Operating altitude up to 3000m

100% full load burn-in test

Conformal coating

No fan suitable for quiet environment

3 years warranty

 

MODEL

VAT-UP300S-5-60L-A

VAT-UP300S-4.6-60L-A

OUTPUT

DC Output

5V

4.6V

Rated Current

60A

60A

CurrentRange     Note 1

0~60A

0~60A

Peak load

70A, last 50mS at 220Vac

Ripple and Noise

25~65℃

150mV

0~25

200mV

Voltage Adj. Range

3.3~5.10V

Voltage Accuracy

±2.0%

Line Regulation

±0.5%

Load Regulation

±2.0%

Set-up Time

≤2.0S (220Vac input, Full load)

Hold up Time

≥5mS(220Vac ,80% load)

Temperature Coefficient

±0.03%/℃

Overshoot

<5%

INPUT

VoltageRange

90Vac~264Vac

FrequencyRange

47Hz~63Hz

Efficiency ( Typical)

90%

90%

AC Current (max.)

<5A

Inrush Current (Typical)

<60A@220Vac      Cold start

Power factor

0.95(220Vac input ,full load)

PROTECTION

Over Power

325W~450W, Hiccup mode, auto recovery

Over Current

65A~90A, Hiccup mode, auto recovery

Shorted Circuit

Long-term mode, auto recovery

Over Temperature

115+5(detect on L4/C1);shut down, auto recovery after the temperature goes down

ENVIRONMENT

Operating amb. Temp. & Hum.

-40~65;  20%~90%RH  No condensing   (refer to the derating curve)

Storage Temp. & Hum.

-40~85;  10%~95%RH  No condensing

SAFETY &EMC

Note 3

Safety Standards

UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006

Withstand Voltage

Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA.

Leakage Current

Input—output: ≤0.25mA     Input—PG: ≤3.5mA  264Vac input, 63Hz

Isolation Resistance

10Mohms

EMI Conduction&Radiation

Compliance toEN55022, EN55024, FCC PART 15   Class B

Harmonic Current

Compliance toEN61000-3-2  Class D

EMSImmunity

Compliance toEN61000-4-2,3,4,5,6,8,11;

OTHERS

MTBF (MIL-HDBK-217F)

More than 200,000Hrs (25, Full load)

Dimension  (L*W*H)

208*60*30mm

Packing

32pcs/CTN

Cooling method

Free air flow (PSU fixed to aluminum heat-sink of 400mm*400mm*2mm)

NOTE

1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃of ambient temperature.

2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 100uF parallel capacitor.

3.  The SPS is considered a component which will be installed into final equipment. We cannot guarantee that the final equipment will meet EMC directives, Final product manufactures must be re-confirm that their product meets EMC directives.