Your present location:HomeProductsLED Display Power Supply / VAT-UP200S-X-P Series
  • Product No.: VAT-UP200S-X-P Series

Universal AC input (90~264Vac)

With Active PFC, PF>0.95

Surge 300Vac for 60S

High Efficiency, long life and High reliability

Output protections: OLP/OVP/SCP/OTP/OPP

1+1 parallel function, current sharing

Wide operating ambient temperature (-40℃~65℃)

Operating altitude up to 5000m

All using 105℃long life electrolytic capacitors.

100% full load burn-in test

Fanless, quiet working

PCB soldering side with conformal coating

2 years warranty

 

MODEL

VAT-UP200S-4.6-P

VAT-UP200S-5-P

OUTPUT

DC Output

4.6V

5V

Rated Current

40A

40A

CurrentRange     Note 1

0~40A

0~40A

Peak load

50A(50mS, 220Vac input)

48A(50mS, 220Vac input)

Ripple and Noise 

Note 2

0~65℃

≤150mV

≤150mV

Voltage Accuracy@-20~65C

±3% 

±3% 

Line Regulation/

±0.5% 

Load Regulation

±2% 

Set-up Time @ 25℃

≤2S (220Vac input, 40A)

Hold up Time

≥5mS (220Vac input, 32A)

Temperature Coefficient

±0.03%/℃

Overshoot and Undershoot

<5.0%

Parallel (current sharing)

Current-unbalance< 10%  (single PS drive 40A load, the voltage of current share bus is 5~6V)

INPUT

VoltageRange   Note 3

90Vac~264Vac

FrequencyRange

47Hz~63Hz

Efficiency ( Typical)

110Vac

87%

89%

220Vac

88%

90%

AC Current (max.)

<3.5A

Inrush Current (Typical)

<15A@220Vac      Cold start

Power Factor @ 25℃

>0.95  (input 220Vac, 40A)

Stand by power consumption

<4W  (input 220Vac)

Leakage Current

Input—output:<0.25mA     Input—PG:<3.5mA   (input 264Vac, 63Hz)

PROTECTION

Over Load

44~65A , hiccup mode, auto recovery

45~55A , hiccup mode, auto recovery

Over Power

193~299W, hiccup mode, auto recovery

225~275W, hiccup mode, auto recovery

Over Voltage

5.1~7V, hiccup mode, auto recovery

5.2~6.5V, hiccup mode, auto recovery

Over Temperature

105+10(detect on temperature controller of PFC);shut down, auto recovery after the temperature goes down to 75℃

Short Circuit

Long-term mode, auto recovery

ENVIRONMENT

Operating amb. Temp. & Hum.

-40~65;  20%~90%RH  No condensing(refer to the derating curve)

Storage Temp. & Hum.

-40~8510%~95%RH  No condensing

SAFETY &EMC  

(Note 4)

Safety Standards

UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006

Withstand Voltage

Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA.

Isolation Resistance

10Mohms

EMI Conduction&Radiation

Compliance to EN55022, EN55024, FCC PART 15 CLASS B 

Harmonic current

Compliance toEN61000-3-2 CLASSD

EMSImmunity

Compliance to EN61000-4-2,3,4,5,6,8,11;

OTHERS

MTBF (MIL-HDBK-217F)

>200000h (25℃, Full load)

Dimension  (L*W*H)

210*50*29mm

Packing

28PCS/CTN, 0.04CBM

Power Good Signal

Working properly: 3.3V

Working abnormally: <0.7V

Reverse voltage start

4.6V output

When output reverse voltage is 5~5.1V, PS starts normally.

5V output

When output reverse voltage is 5~10V, PS starts normally.

Cooling method

Cooling by free air convection

NOTE

1.All parameters NOT specially mentioned are measured at rated input, rated load and 25of ambient temperature.

2.Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.

3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttp://www.powerld.com.cn.