Your present location:HomeProductsLED Display Power Supply / VAT-UP300L Series
  • Product No.: VAT-UP300L Series

Universal AC input (90~264Vac)

With Active PFC, PF>0.95

High Efficiency, long life and High reliability

Surge 300Vac for 60s

Output protections: OLP/OVP/SCP/OPP

Wide operating ambient temperature (-40℃~65℃)

Operating altitude up to 5000m

All using 105℃long life electrolytic capacitors.

100% full load burn-in test

Fanless, quiet working

PCB both side with conformal coating

2 years warranty

Application: Indoor LED display, small pitch display. Rental LED display

 

MODEL

VAT-UP300L-5-E

VAT-UP300L-4.2-E

OUTPUT

DC Output

5V

4.2V

Rated Current

60A

60A

CurrentRange     Note 1

0~60A

3~60A

Peak load

70A(50mS, 220Vac input)

Ripple and Noise 

Note 2

0~65℃

≤200mV 100Mbandwidth; ≤150MV 20Mbandwidth

-40℃

≤400mV 100Mbandwidth

Voltage Accuracy

±3%

Line Regulation/

±0.5%

Load Regulation

±2%

Set-up Time

≤3S (220Vac input, 60A)

Hold up Time

≥4mS (220Vac input, 60A)

Temperature Coefficient

±0.03%/℃

Overshoot and Undershoot

<5.0%

INPUT

VoltageRange   Note 3

90Vac~264Vac

FrequencyRange

47Hz~63Hz

Efficiency ( Typical)

110Vac input

≥87%

≥86%

230Vac input

≥90%

≥88%

AC Current (max.)

<5A

Inrush Current (Typical)

<30A@220Vac      Cold start

Power Factor @ 25℃

>0.95  (input 220Vac, 60A)

Leakage Current

Input—output:<0.25mA     Input—PG:<3.5mA   (input 264Vac, 63Hz)

PROTECTION

Over Load

63~80A , hiccup mode, auto recovery

63~90A , hiccup mode, auto recovery

Over Power

350~450W, hiccup mode, auto recovery

264~378W, hiccup mode, auto recovery

Over Voltage

5.2~6.5V, constant voltage

4.5~5.5V, constant voltage

Over Temperature

95+5(detect on temperature controller);shut down, auto recovery after the temperature goes down to 65℃ 

Short Circuit

Long-term mode, auto recovery

ENVIRONMENT

Operating amb. Temp. & Hum.

-40℃~65℃;  20%~90%RH  No condensing(refer to the derating curve)

Storage Temp. & Hum.

-40℃~85℃;  10%~95%RH  No condensing

SAFETY &EMC  

(Note 4)

Safety Standards

UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006

Withstand Voltage

Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA.

Isolation Resistance

10Mohms

EMI Conduction&Radiation

Compliance to EN55022, EN55024, FCC PART 15   Class B

Harmonic Current

Compliance to EN61000-3-2  Class D

EMSImmunity

Compliance to EN61000-4-2,3,4,5,6,8,11

OTHERS

MTBF (MIL-HDBK-217F)

>200000h (25℃, Full load)

Dimension  (L*W*H)

190×99×29.8mm

Packing

TBD

Cooling method

Cooling by free air convection 

NOTE

1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.

2.Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.

3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttp://www.powerld.com.cn.