Your present location:HomeProductsAC/DC Power SuppliesOpen Frame Single Output / PS-60 Series Switching Power Supply
  • Product No.: PS-60 Series

Universal AC input 90~264Vac

High Efficiency, low power consumption

Output protections: SCP/OVP/ OLP/OPP

Wide operating ambient temperature (-25℃~70℃)

All using 105℃long life electrolytic capacitors.

100% full load burn-in test

3 years warranty

 

MODEL

PS-60-5

PS-60-12

PS-60-15

PS-60-24

PS-60-48

OUTPUT

DC Output

5.0V

12.0V

15.0V

24.0V

48.0V

Rated Current

8.0A

4.5A

3.6A

2.5 A

1.25A

Ripple and Noise 

Note 2

0~70℃

<50mV

<120mV

<150mV

<240mV

<240mV

-25℃~0℃

<200mV

<200mV

<150mV

<240mV

<240mV

Voltage ADJ.  Range

-5% ~ +10% of rated voltage

Voltage Accuracy

±3.0%

Line Regulation

±0.5%

Load Regulation

±2.0%

Set-up Time

1.0S (230Vac input, Full load)

Hold up Time

20mS(230Vac input, Full load)

Temperature Coefficient

±0.03%/℃

Overshoot and Undershoot

<5.0%

INPUT

VoltageRange   Note 3

90Vac~264Vac, 127Vdc~370Vdc

FrequencyRange

47Hz-63Hz

Efficiency ( Typical)

81%

84%

84%

86%

87%

AC Current (max.)

1.5A

Inrush Current (Typical)

[email protected]    [email protected]      Cold start

Leakage Current

<0.25mA

PROTECTION

Over Load

105%~180% of rated output current, hiccup mode, auto recovery

Over Power

105%~180% of rated output power, hiccup mode, auto recovery

Over Voltage

105%~150% of rated output voltage, Constant voltage

Shorted Circuit

Long-term mode, auto recovery

ENVIRONMENT

Operating amb. Temp. & Hum.

-25℃~70℃;  20%~90%RH  No condensing (refer to the derating curve)

Storage Temp. & Hum.

-30℃~85℃;  10%~95%RH  No condensing

SAFETY &EMC  

(Note 4)

Safety Standards

UL60950-1; EN60950-12006

Withstand Voltage

Primary-Secondary:3.0KVac; 10mA .

Isolation Resistance

100M ohms

EMI Conduction&Radiation

Compliance to EN55022, FCC PRAT15 B Class B

Harmonic Current

Compliance to EN61000-3-2,-3

EMSImmunity

Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level

OTHERS

MTBF (MIL-HDBK-217F)

More than 200,000Hrs (25℃, Full load) MIL-217 Method 2 Components Stress Method

Dimension  (L*W*H)

101.6×50.8×30mm

Packing

60PCS/CTN, 12KGS, 0.024CBM

Cooling method

Cooling by free air convection

NOTE

1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.

2.Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor.

3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttp://www.powerld.com.cn.