Your present location:HomeProductsAC/DC Power SuppliesEnclosed Single Output / PDF-600 Series Switching Power Supply
  • Product No.: PDF-600 Series

600W AC/DC power supply

Built-in active PFC function,PF>0.96  

Output protection: SCP/OLP/OVP/OTP

Wide operating ambient temperature (-30~70℃), 100% @50℃, 80%@70℃

Using ZVS technology to reduce power dissipation

Built in AC inrush current limiting circuit(<20A)

Built in Remote Sense Function

Conformal coating at PCB both sides

Suitable for harsh Environment 

1 U low profile  218*116.5*41mm(L*W*H)

Applications:  The industry, Medical, Lighting, Communication etc. equipments which required  high reliablity and stability  power supplies

 

MODEL

PDF-600-12

PDF-600-24

PDF-600-27

PDF-600-36

PDF-600-48

OUTPUT

DC Output

12V

24V

27V

36V

48V

Rated Current (100~127Vac)

34A

22A

18V

14A

11A

Rated Current (128~264Vac)

42A

26.5A

23V

17.5A

13.6A

Ripple and Noise

Note 2

0-70℃

120mV

150mV

150mV

150mV

200mV

-30℃

180mV

150mV

150mV

150mV

200mV

Voltage ADJ.  Range

-5%~+10% of rated output voltage

Voltage Accuracy

±2.0%

±2.0%

±2.0%

±2.0%

±2.0%

Line Regulation

±0.5%

±0.5%

±0.5%

±0.5%

±0.2%

Load Regulation

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

Set-up Time

1.5S (230Vac input, Full load), 3S (115Vac input, Full load)

Hold up Time

16mS/ (230Vac input, Full load)

Temperature Coefficient

±0.05%/℃

Overshoot and Undershoot

<5.0%

INPUT

VoltageRange  

90Vac~264Vac,127Vdc~370Vdc

FrequencyRange

47Hz--63Hz

Power Factor(Typical)

PF0.98/115VAC    PF0.96/230VAC

Efficiency ( Typical)

88%

89%

89%

90%

90%

AC Current (max.)

<7A

Inrush Current (Typical)

<[email protected]       Cold start

Leakage Current

Input—output: 0.1mA     Input—PG: 0.75mA

PROTECTION

Over Load

110%~135% of rated output current, constant current

Over Temperture

105+5℃(detect on Mosfet temperature);shut down,auto recovery after the temperature goes down to 75℃

Over Voltage

110%~150% of rated voltage; constant voltage

Short Circuit

Long-term mode, constant current, auto recovery

ENVIRONMENT

Operating amb. Temp. & Hum.

-30℃~70℃;  20%~90%RH  No condensing  (refer to derating curve)

Storage Temp. & Hum.

-40℃~85℃;  10%~95%RH  No condensing

SAFETY &EMC   

(Note 3)

Safety Standards

UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006

Withstand Voltage

Primary-Secondary:3.0KVac; 10mA .Primary-PG:1.5KVac; 10mA. Secondary-PG:0.5KVac;10mA.

Isolation Resistance

100M ohms

EMI Conduction&Radiation

Compliance to EN55022,  CLASS B

Harmonic Current

Compliance to EN61000-3-2, class D

EMSImmunity

Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level

OTHERS

MTBF (MIL-HDBK-217F)

More than 200,000Hrs (25℃, Full load)

Dimension  (L*W*H)

218×116.5×41mm

Packing

6PCS/CTN, 8.7KGS, 0.04CBM

Cooling method

Fored air cooling(Built-in fan)

NOTE

1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.

2.Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.

3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.