  • Product No.: GKF-200 Series

200W AC/DC power supply, 90Vac~264Vac input                                                          

Built-in active PFC,PF>0.95                                 

SCP/OLP/OVP/OTP  Protections                                             

All using 105℃ long life electrolytic capacitors.

Operating altitude up to 5000m
Easy assembling from top side
PCB  both sides with conformal coating 199*98*50mm(L*W*H)

Applications: CNC system, Industrial Robot, man-machine interface,PLC, DC motors.

 

MODEL

GKF-200-5II

GKF-200-12II

GKF-200-24II

GKF-200-36II

GKF-200-48II

OUTPUT

DC Output

5.0V

12V

24V

36V

48V

Rated Current

40A

16.7A

8.4A

5.6A

4.2A

CurrentRange     Note 1

0~40A

0~16.7A

0~8.4A

0~5.6A

0~4.2A

Ripple and Noise   Note 2

<150mV

<150mV

<200mV

<200mV

<200mV

Voltage ADJ.  Range

-5%~+10% of rated output voltage

Voltage Accuracy

±1.0%

Line Regulation

±0.5%

Load Regulation

±1.0%

Set-up Time

≤2S (230Vac input, Full load)

Hold up Time

≥10mS (230Vac input, Full load)

Temperature Coefficient

±0.03%/℃

Overshoot and Undershoot

<5.0%

INPUT

VoltageRange  

85Vac~264Vac,120Vdc~370Vdc

FrequencyRange

47Hz--63Hz

Power Factor(Typical)

PF0.98/115VAC    PF0.95/230VAC

Efficiency ( Typical)

79%

84%

86%

86.5%

87.5%

AC Current (max.)

< 3.5A

Inrush Current (Typical)

<[email protected]   <[email protected]   Cold start

Leakage Current

Input—output:<0.25mA     Input—PG:<1.0mA

PROTECTION

Over Load

105%~150% of rated output current, Hiccup mode, auto recovery

Over power

105%~150% of rated output power, hiccup mode, auto recovery

Short Circuit

Long-term mode, auto recovery

ENVIRONMENT

Operating amb. Temp. & Hum.

-25℃~70℃;  20%~90%RH  No condensing(refer to the derating curve)

Vibration

10 ~ 150Hz, 2G 10min./1cycle, period for60min. each along X,Y, Z axes

Storage Temp. & Hum.

-40℃~85℃;  10%~95%RH  No condensing

SAFETY &EMC   

(Note 3)

Safety Standards

UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006

Withstand Voltage

Primary-Secondary: 3.0KVac; ≤10mA .Primary-PG: 1.5KVac; ≤10mA. Secondary-PG: 0.5KVDC; ≤10mA.

Isolation Resistance

≥100M ohms

EMI Conduction&Radiation

Compliance to EN55022, Class B

Harmonic Current

Compliance to EN61000-3-2, Class D

EMSImmunity

Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level

OTHERS

MTBF (MIL-HDBK-217F)

More than 200,000Hrs (25℃, Full load)

Dimension  (L*W*H)

199×99×50mm

Packing

12PCS/CTN, 11.4KGS, 0.04CBM

Cooling method

Cooling by forced air (built-in DC fan)

NOTE

1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.

2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.

3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on http://www.powerld.com.