Your present location:HomeProductsAC/DC Power SuppliesEnclosed Single Output / GKF-150 Series
  • Product No.: GKF-150 Series

150W AC/DC power supply, 90Vac~264Vac input

Built-in Active PFC function, PF>0.95

OLP/OVP/SCP/OTP/OPP  protections
Wide operating ambient temp (-20℃~70℃)                       

PCB soldering side with conformal coating

Suitable for harsh Environment                                            

Easy assembling from top side

Compact size , 160*99*38mm(L*W*H)

Applications: CNC system, Industrial Robot, man-machine interface,PLC, DC motors

 

MODEL

GKF-150-12

GKF-150-15

GKF-150-24

GKF-150-48

OUTPUT

DC Output

12V

15V

24V

48V

Rated Current

12.5A

10A

6.3A

3.2A

CurrentRange     Note 1

0~12.5A

0~10A

0~6.3A

0~3.2A

Ripple and Noise   Note 2

0~70℃

≤100mV

≤100mV

≤100mV

≤100mV

-20~0℃

≤200mV

≤200mV

≤200mV

≤200mV

Voltage ADJ.  Range

10.8~13.2V

13.5~16.5V

21.6~26.4V

43.2~52.8V

Voltage Accuracy

±2.0%

±2.0%

±2.0%

±2.0%

Line Regulation

±0.5%

±0.5%

±0.5%

±0.5%

Load Regulation

±2.0%

±2.0%

±1.0%

±1.0%

Set-up Time

≤3S /115Vac≤2S /230Vac

Hold up Time

≥10mS  (220Vac input, Full load)

Temperature Coefficient

±0.03%/

Overshoot and Undershoot

<5.0%

INPUT

VoltageRange  

90Vac~264Vac

FrequencyRange

47Hz~63Hz

Power factor (typical)

PF[email protected], PF[email protected]

Efficiency (Typical) 230Vac input

≥86%

≥87%

≥87%

≥88%

AC Current (max.)

2 A

Inrush Current (Typical)

30A/115Vac,<45A/230Vac      Cold start

Leakage Current

Input—output: ≤0.25mA    Input—PG: ≤3.5mA

PROTECTION

Over Load

105%~150% of rated output current, hiccup mode, auto recovery

Over power

105%~150% of rated output current, hiccup mode, auto recovery

Over Voltage

115%~150% of rated output voltage, hiccup mode, auto recovery

Over Temperature

105+5(detect on Mosfet temperature);shut down,auto recovery after the temperature goes down to 60℃

Short Circuit

Long-term mode, auto recovery

ENVIRONMENT

Operating amb. Temp. & Hum.

-20~70℃;  20%~90%RH  No condensing (refer to the derating curve)

Storage Temp. & Hum.

-30~85℃;  10%~95%RH  No condensing

SAFETY &EMC

Note 3

Safety Standards

UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006

Withstand Voltage

Primary-Secondary:3.0KVac; 10mA .Primary-PG:1.5KVac; 10mA. Secondary-PG:0.5KVDC;10mA.

Isolation Resistance

100Mohms

EMSEmission

Compliance to EN55022 Class B

Harmonic Current

Compliance to EN61000-3-2, Class A

EMC Immunity

Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level

OTHERS

MTBF (MIL-HDBK-217F)

More than 200,000Hrs (25℃, Full load)

Dimension  (L*W*H)

160×98.3×38mm

Packing

20PCS/CTN, 14KGS, 0.04CBM

Cooling method

Cooling by free air convection

NOTE

1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.

2.Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor.

3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be reconfirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttp://www.powerld.com.