Your present location:HomeProductsAC/DC Power SuppliesEnclosed Single Output / GKF-100 Series
  • Product No.: GKF-100 Series

100W AC/DC power supply,  90Vac~264Vac input

Built-in Active PFC function, PF>0.93

Suitable for peak load application

PCB soldering side with conformal coating

Withstand 300Vac surge input for 5 secs

OLP/SCP/OPP Protections

Applications: CNC system, Industrial Robot, man-machine interface,PLC, DC motors.

 

MODEL

GKF-100-5

GKF-100-12

GKF-100-24

GKF-100-48

OUTPUT

DC Output

5V

12V

24V

48V

Rated Current

20A

8.5A

4.2A

2.2A

CurrentRange     Note 1

0~20A

0~8.5A

0~4.2A

0~2.2A

Ripple and Noise   Note 2

0~70℃

≤150mV

≤150mV

≤150mV

≤150mV

-20~0℃

≤150mV

≤150mV

≤150mV

≤200mV

Voltage ADJ.  Range

3.3V—5.5V

10~15V

21~27V

43.2~52.8V

Voltage Accuracy

±2.0%

±2.0%

±1.0%

±1.0%

Line Regulation

±0.5%

±0.5%

±0.5%

±0.5%

Load Regulation

±2.0%

±2.0%

±1.0%

±1.0%

Set-up Time

≤4S @115Vac,≤2S @230Vac

Hold up Time

≥12mS  (230Vac input, Full load)

Temperature Coefficient

±0.03%/℃

Overshoot and Undershoot

<5.0%

INPUT

VoltageRange  

90Vac~264Vac

FrequencyRange

47Hz~63Hz

Power factor (typical)

PF>[email protected], PF[email protected]

Efficiency (Typical) 230Vac input

≥84%

≥87%

≥88%

≥88%

AC Current (max.)

<1.5 A

Inrush Current (Typical)

[email protected],<[email protected]      Cold start

Leakage Current

Input—output: ≤0.25mA    Input—PG: ≤3.5mA

PROTECTION

Over Load

110%~150% of rated output current, hiccup mode, auto recovery

Over power

110%~150% of rated output current, hiccup mode, auto recovery

Short Circuit

Long-term mode, auto recovery

ENVIRONMENT

Operating amb. Temp. & Hum.

-20℃~60℃;  20%~90%RH  No condensing (refer to the derating curve)

Storage Temp. & Hum.

-30℃~85℃;  10%~95%RH  No condensing

SAFETY &EMC

Note 3

Safety Standards

UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006

Withstand Voltage

Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; 10mA. Secondary-PG:0.5KVDC;≤10mA.

Isolation Resistance

100Mohms

EMSEmission

Compliance to EN55022 Class B

Harmonic Current

Compliance to EN61000-3-2, Class A

EMC Immunity

Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level

OTHERS

MTBF (MIL-HDBK-217F)

More than 200,000Hrs (25℃, Full load)

Dimension  (L*W*H)

129×98.3×37.6mm

Packing

30PCS/CTN, 14.6KGS, 0.04CBM

Cooling method

Cooling by free air convection

NOTE

1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.

2.Measured at 20MHz of bandwidth

3.The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.