Your present location:Home
  • Product No.: VAT-UP200L-5

AC input: 90 ~ 264VAC

High efficiency, long life and high reliability

Output protections: OLP/SCP/OVP/OTP

Built-in active PFC function, PF>0.95

Wide operating ambient temperature  (-40℃~65℃)

Altitude up to 5000m

All using 105℃ long life electrolytic capacitors

100% full load burn-in test

Conformal coating

No load power consumption < 6W

3 years warranty

 

MODEL

VAT-UP200L-5

OUTPUT

DC Output

5V

Rated Current

40A

CurrentRange     Note 1

3~40A

Peal load

50A, last 50mS at 220Vac

Ripple and Noise 

Note 2

0~65℃

200mV

-40~0

400mV

Voltage Accuracy

±2.0%

Line Regulation

±0.5%

Load Regulation

±2.0%

Set-up Time

2.0S (220Vac input, Full load)

Hold up Time

5mS(220Vac input ,32A)

Temperature Coefficient

±0.03%/℃

Overshoot and Undershoot

<5%

INPUT

VoltageRange

90Vac~264Vac

FrequencyRange

47Hz~63Hz

Efficiency ( Typical) @220Vac

88%

AC Current (max.)

<3.5A

Inrush Current (Typical)

50A@220Vac      Cold start

Power factor

0.96(230Vac input ,full load) ; 0.98@110Vac

Standby power

6W@220Vac

Leakage Current

Input—output:<0.25mA     Input—PG:<3.5mA  264Vac input, 63Hz

PROTECTION

Over Power

220~350W, Hiccup mode, auto recovery

Over Current

44~60A, Hiccup mode, auto recovery

Over Voltage

5.2~6.5V, Hiccup mode, auto recovery

Shorted Circuit

Long-term mode, auto recovery

Over Temperature

115℃+5℃(detect on transformer);shut down, auto recovery after the temperature goes down

ENVIRONMENT

Operating amb. Temp. & Hum.

-40~65;  20%~90%RH  No condensing   (refer to the derating curve)

Storage Temp. & Hum.

-40~85;  10%~95%RH  No condensing

SAFETY &EMC

Note 3

Safety Standards

UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006

Withstand Voltage

Primary-Secondary:3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG:0.5KVDC/10mA.

Isolation Resistance

10Mohms

EMI Conduction & Radiation

Compliance to EN55022, Class B

Harmonic Current

Compliance to EN61000-3-2, Class D

EMSImmunity

Compliance to EN61000-4-2,3,4,5,6,8;

OTHERS

MTBF (MIL-HDBK-217F)

More than 200,000Hrs (25℃, Full load)

Dimension  (L*W*H)

190×99×29.8mm

Packing

/

Cooling method

Free air flow

NOTE

1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃of ambient temperature.

2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 100uF parallel capacitor.

3.  The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.