n Features:
Ø Universal AC input/ Full range
Ø Built-in active PFC function,PF>0.93
Ø High Efficiency, and High reliability
Ø Output protections: OLP/OVP/SCP
Ø All using 105℃ long life electrolytic capacitors.
Ø 100% full load burn-in test
Ø 3 years warranty
SPECIFICATION
|
MODEL
|
PDF-150-5
|
PDF-150-12
|
PDF-150-15
|
PDF-150-24
|
PDF-150-36
|
PDF-150-48
|
|
OUTPUT
|
DC Output
|
5.0V
|
12V
|
15V
|
24V
|
36V
|
48V
|
|
Rated Current
|
30A
|
12.5A
|
10.0A
|
6.3A
|
4.1A
|
3.2A
|
|
Current Range Note 1
|
0~30A
|
0~12.5A
|
0~10A
|
0~6.3A
|
0~4.1A
|
0~3.2A
|
|
Ripple and Noise Note 2
|
100mV
|
100Mv
|
100mV
|
150mV
|
240mV
|
240mV
|
|
Voltage ADJ. Range
|
4.0V~6.0V
|
10.0V~14.0V
|
12.0V~18.0V
|
20.0V~28.0V
|
32V~40V
|
42.0V~54V
|
|
Voltage Accuracy
|
±2.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
|
Line Regulation
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
|
Load Regulation
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
|
Set-up Time
|
<2.0S (115Vac input, Full load);<1.0S (230Vac input, Full load)
|
|
Hold up Time
|
>20mS(115Vac/230Vac input, Full load)
|
|
Temperature Coefficient
|
±0.03%/℃
|
|
Overshoot and Undershoot
|
<5.0%
|
|
INPUT
|
Voltage Range
|
85Vac~264Vac
|
|
Frequency Range
|
47Hz--63Hz
|
|
Power Factor(Typical)
|
PF>0.98/115VAC PF>0.94/230VAC
|
|
Efficiency ( Typical)
|
115Vac input
|
80%
82%/230Vac
|
83%
|
83%
|
83%
|
83%
|
84%
|
|
230Vac input
|
82%
|
86%
|
86%
|
86%
|
86%
|
87%
|
|
AC Current (max.)
|
2.0A
|
|
Inrush Current (Typical)
|
30A@115Vac; 60A@230Vac Cold start
|
|
Leakage Current
|
Input—output:<0.25mA Input—PG:<3.5mA
|
|
PROTECTION
|
Over Load
|
105%~150% of rated output current, hiccup mode, auto recovery
|
|
Over Voltage
|
110%~150% of rated output voltage, shut dow(5V) 110%~130% of rated output voltage, shut dow(48V)
110%~140% of rated output voltage, shut dow(12V/15V/24V) ,
|
|
Short Circuit
|
Long-term mode, auto recovery
|
|
ENVIRONMENT
|
Operating amb. Temp. & Hum.
|
-10℃~60℃; 20%~90%RH No condensing;please( refer to the derating curve)
|
|
Storage Temp. & Hum.
|
-20℃~85℃; 10%~95%RH No condensing
|
|
SAFETY &EMC
(Note3)
|
Safety Standards
|
UL60950-1; EN60950-1:2006
|
|
Withstand Voltage
|
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA.
|
|
Isolation Resistance
|
≥100M ohms
|
|
EMI Conduction&Radiation
|
Compliance to EN55022 ClassB
|
|
Harmonic Current
|
Compliance to EN61000-3-2,17625.1-2003
|
|
EMS Immunity
|
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA
|
|
OTHERS
|
MTBF (MIL-HDBK-217F)
|
More than 100,000Hrs (25℃, Full load)
|
|
Dimension (L*W*H)
|
194×99×50mm
|
|
Packing
|
20PCS/CTN. G.W:15.2kgs
|
|
Cooling method
|
Cooling by free air convection
|
|
NOTE
|
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
|
|