产品展示
PD-60

n  Features:

Ø  Universal AC input/ Full range

Ø  High Efficiency, and High reliability

Ø  Output protections: OLP/OVP/SCP

Ø  Wide operating ambient temperature (-20~70)

Ø  All using 105 long life electrolytic capacitors.

Ø  100% full load burn-in test

Ø  3 years warranty      

 

SPECIFICATION                                                      

MODEL

PD-60-5

PD-60-12

PD-60-15

PD-60-24

PD-60-48

OUTPUT

DC Output

5.0V

12.0V

15.0V

24.0V

48.0V

Rated Current

10A

5A

4.0A

2.5A

1.25A

Current Range     

0~10A

0~5.0A

0~4.0A

0~2.5A

0~1.25A

Ripple and Noise 

Note 2

-20~70

 

<50mV

<50mV

<100mV

<100mV

<200mV

Voltage ADJ.  Range

4.6V-5.5V

11.0V-13.0V

13.7V-16.0V

22.0V-25.3V

45.3V-51.3V

Voltage Accuracy

±2.0%

±2.0%

±2.0%

±2.0%

±2.0%

Line Regulation

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load Regulation

±2.0%

±2.0%

±2.0%

±2.0%

±2.0%

Set-up Time

2S (115Vac input, Full load); 1.0S (230Vac input, Full load)

Hold up Time

10mS(115Vac input, Full load); 20mS(230Vac input, Full load)

Temperature Coefficient

±0.03%/

Overshoot and Undershoot

<5.0%

INPUT

Voltage Range  

88Vac~264Vac,124~370Vdc

Frequency Range

47Hz--63Hz

Efficiency ( Typical)

115Vac input

75%

81%

81%

83%

84%

230Vac input

76%

82%

82%

83%

85%

AC Current (max.)

1.5A

1.5A

2.5A

1.5A

1.5A

1.5A

Inrush Current (Typical)

<40A@115Vac    <60A@230Vac      Cold start

Leakage Current

<0.25mA@115Vac     <3.5mA@230Vac

PROTECTION

Over Load

105%~150% of rated output current, hiccup mode, auto recovery

Over Voltage

110%~125% of rated output voltage, shut down(48V)        120%~150% of rated output voltage, shut down(5V),

110%~140% of rated output voltage, shut down(15V,24V),     110%~133% of rated output voltage, shut down(12V),

Short Circuit

Long-term mode, auto recovery

ENVIRONMENT

Operating amb. Temp. & Hum.

-20~70;  20%~90%RH  No condensing((refer to the derating curve)

Storage Temp. & Hum.

-40~85;  10%~95%RH  No condensing

SAFETY &EMC  

(Note 3)

Safety Standards

UL60950-1; EN60950-12006

Withstand Voltage

Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVdc;≤10mA.

Isolation Resistance

≥100M ohms

EMI Conduction&Radiation

Compliance to EN55022(CISPR22)ClassB

EMS Immunity

Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA

OTHERS

MTBF (MIL-HDBK-217F)

More than 200,000Hrs (25, Full load)

Dimension  (L*W*H)

129×98×38mm

Packing

30PCS/CTN, 14.2KGS, 0.044CBM

Cooling method

Cooling by free air convection

 

NOTE

1.     All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25 of ambient temperature.

2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.

3.        The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.

4.  Powerld offer accessories for Din-35 rail bar. Please contact sales staff for details.