MODEL
|
PD-150-5
|
PD-150-12
|
PD-150-15
|
PD-150-24
|
PD-150-48
|
|
OUTPUT
|
DC Output
|
5V
|
12V
|
15V
|
24V
|
48V
|
|
Rated Current
|
26A
|
12.5A
|
10A
|
6.5 A
|
3.3A
|
|
Current Range Note 1
|
0~26A
|
0~12.5A
|
0~10A
|
0~6.5A
|
0~3.3A
|
|
Ripple and Noise
Note 2
|
0~70℃
|
80mV
|
120mV
|
120mV
|
120mV
|
200mV
|
|
-20℃
|
100mV
|
150 mV
|
180 mV
|
150 mV
|
300 mV
|
|
Voltage ADJ. Range
|
4.2V-6.0V
|
10.0V-14.0V
|
13.0V-17.0V
|
21.0V-28.0V
|
43.0V-54.0V
|
|
Voltage Accuracy
|
±2.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
|
Line Regulation/
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
|
Load Regulation
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
|
Set-up Time
|
<2.0S (115Vac input, Full load); <1.0S (230Vac input, Full load)
|
|
Hold up Time
|
>10mS(115Vac input, Full load); >20mS(230Vac input, Full load)
|
|
Temperature Coefficient
|
±0.03%/℃(0℃~50℃)
(
|
|
Overshoot and Undershoot
|
<5.0%
|
|
INPUT
|
Voltage Range Note 3
|
88Vac/176Vac~132Vac/264Vac
|
|
Frequency Range
|
47Hz~63Hz
|
|
Efficiency ( Typical)
|
115Vac input
|
78%
|
83%
|
83%
|
84%
|
85%
|
|
230Vac input
|
79%
|
83%
|
84%
|
85%
|
86%
|
|
AC Current (max.)
|
≤3.5A/2.0A
|
|
Inrush Current (Typical)
|
20A@115Vac 40A@230Vac Cold start
|
|
Leakage Current
|
<0.25mA/115Vac <2.0mA/230Vac
|
|
PROTECTION
|
Over Load
|
105%~150% of rated output current , hiccup mode,auto recovery
|
|
Over Voltage
|
120%~150% of rated output voltage, shut down
|
|
Short Circuit
|
Long-term mode, auto recovery
|
|
ENVIRONMENT
|
Operating amb. Temp. & Hum.
|
-20℃~70℃; 20%~90%RH No condensing(refer to the derating curve)
|
|
Storage Temp. & Hum.
|
-40℃~85℃; 10%~95%RH No condensing
|
|
SAFETY &EMC
(Note 4)
|
Safety Standards
|
UL60950-1; EN60950-1:2006
|
|
Withstand Voltage
|
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA.
|
|
Isolation Resistance
|
≥100M ohms
|
|
EMI Conduction&Radiation
|
Compliance to EN55022(CISPR22)ClassB
|
|
Harmonic Current
|
Compliance to EN61000-3-2,-3
|
|
EMS Immunity
|
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA
|
|
OTHERS
|
MTBF (MIL-HDBK-217F)
|
More than 100,000Hrs (25℃, Full load)
|
|
Dimension (L*W*H)
|
199×98×38mm
|
|
Packing
|
20PCS/CTN, G.W:15kgs
|
|
Cooling method
|
Cooling by free air convection
|
|
NOTE
|
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
3. AC input range selected by switch.
4. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
|