PD-150

n         Features:

Ø         AC input selectable by switch(115Vac/230Vac)

Ø         High Efficiency, and High reliability

Ø         Output protections: OLP/OVP/SCP

Ø         Wide operating ambient temperature (-20~70)

Ø         All using 105 long life electrolytic capacitors.

Ø         100% full load burn-in test

Ø         3 years warranty     

 

SPECIFICATION                                                      

MODEL

PD-150-5

PD-150-12

PD-150-15

PD-150-24

PD-150-48

OUTPUT

DC Output

5V

12V

15V

24V

48V

Rated Current

26A

12.5A

10A

6.5 A

3.3A

Current Range     Note 1

0~26A

0~12.5A

0~10A

0~6.5A

0~3.3A

Ripple and Noise 

Note 2

0~70℃

80mV

120mV

120mV

120mV

200mV

-20℃

100mV

150 mV

180 mV

150 mV

300 mV

Voltage ADJ.  Range

4.2V-6.0V

10.0V-14.0V

13.0V-17.0V

21.0V-28.0V

43.0V-54.0V

Voltage Accuracy

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

Line Regulation/

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load Regulation

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

Set-up Time

2.0S (115Vac input, Full load); 1.0S (230Vac input, Full load)

Hold up Time

10mS(115Vac input, Full load); 20mS(230Vac input, Full load)

Temperature Coefficient

±0.03%/℃(0℃~50℃)

(

Overshoot and Undershoot

<5.0%

INPUT

Voltage Range   Note 3

88Vac/176Vac~132Vac/264Vac

Frequency Range

47Hz~63Hz

Efficiency ( Typical)

115Vac input

78%

83%

83%

84%

85%

230Vac input

79%

83%

84%

85%

86%

AC Current (max.)

3.5A/2.0A

Inrush Current (Typical)

20A@115Vac    40A@230Vac      Cold start

Leakage Current

<0.25mA/115Vac    <2.0mA/230Vac

PROTECTION

Over Load

105%~150% of rated output current , hiccup mode,auto recovery

Over Voltage

120%~150% of rated output voltage, shut down

Short Circuit

Long-term mode, auto recovery

ENVIRONMENT

Operating amb. Temp. & Hum.

-20℃~70℃;  20%~90%RH  No condensing(refer to the derating curve)

Storage Temp. & Hum.

-40℃~85℃;  10%~95%RH  No condensing

SAFETY &EMC  

(Note 4)

Safety Standards

UL60950-1; EN60950-12006

Withstand Voltage

Primary-Secondary:3.0KVac; 10mA .Primary-PG:1.5KVac; 10mA. Secondary-PG:0.5KVDC;10mA.

Isolation Resistance

100M ohms

EMI Conduction&Radiation

Compliance to EN55022(CISPR22)ClassB

Harmonic Current

Compliance to EN61000-3-2,-3

EMS Immunity

Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA

OTHERS

MTBF (MIL-HDBK-217F)

More than 100,000Hrs (25℃, Full load)

Dimension  (L*W*H)

199×98×38mm

Packing

20PCS/CTN, G.W:15kgs

Cooling method

Cooling by free air convection

 

NOTE

1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.

2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.

3.  AC input range selected by switch.

4.  The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.