n Features:
Ø No Load power consumption<0.5W
Ø Withstand 300VA surge input for 5 sec.
Ø High Efficiency, High reliability and long life
Ø Output protections: OLP/OVP/SCP
Ø Wide operating ambient temperature (-20℃~70℃)
Ø All using 105℃ long life electrolytic capacitors.
Ø 100% full load burn-in test
Ø Terminal block with plastic cover
Ø 3 years warranty
SPECIFICATION
|
MODEL
|
PD-35-5
|
PD-35-12
|
PD-35-15
|
PD-35-24
|
PD-35-48
|
|
OUTPUT
|
DC Output
|
5V
|
12V
|
15V
|
24V
|
48V
|
|
Rated Current
|
6A
|
3A
|
2.3A
|
1.5A
|
0.75A
|
|
Current Range
|
0~6A
|
0~3A
|
0~2.3A
|
0~1.5A
|
0~0.75A
|
|
Ripple and Noise
Note 2
|
0~70℃
|
<50mV
|
<80mV
|
<120mV
|
<120mV
|
<180 mV
|
|
-20~0℃
|
<80mV
|
<180mV
|
<200mV
|
<200mV
|
<240mV
|
|
Voltage ADJ. Range
|
4.75V~5.5V
|
11.4V~13.2V
|
14.3~16.5V
|
22.8V~26.4V
|
45.6V~52.8V
|
|
Voltage Accuracy
|
±3.0%
|
±3.0%
|
±3.0%
|
±3.0%
|
±3.0%
|
|
Line Regulation
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
|
Load Regulation
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
|
Set-up Time
|
<1S (230Vac input, Full load);
|
|
Hold up Time
|
>20mS(230Vac input, Full load); >10mS(120Vac input, Full load)
|
|
Temperature Coefficient
|
±0.03%/℃
|
|
Overshoot and Undershoot
|
<5.0%
|
|
INPUT
|
Voltage Range
|
90Vac~264Vac,127~370Vdc
|
|
Frequency Range
|
47Hz~63Hz
|
|
Efficiency ( Typical)
|
115Vac input
|
79%
|
83%
|
85%
|
86%
|
87%
|
|
230Vac input
|
80%
|
84%
|
86%
|
87%
|
88%
|
|
AC Current (max.)
|
<1A(max)
|
|
Inrush Current (Typical)
|
<50A@230Vac Cold start
|
|
Leakage Current
|
Input—output:<3.5mA Input—PG:<0.25mA
|
|
PROTECTION
|
Over Load
|
105%~150% of rated output current, constant power,auto recovery
|
|
Over Voltage
|
105%~150% of rated output voltage, Constant Voltage
|
|
Short Circuit
|
Long-term mode, auto recovery
|
|
ENVIRONMENT
|
Operating amb. Temp. & Hum.
|
-20℃~70℃; 20%~90%RH No condensing((refer to the derating curve)
|
|
Storage Temp. & Hum.
|
-40℃~85℃; 10%~95%RH No condensing
|
|
SAFETY &EMC
Note 3
|
Safety Standards
|
UL60950-1; EN60950-1:2006
|
|
Withstand Voltage
|
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA.
|
|
Isolation Resistance
|
≥100M ohms
|
|
EMI Conduction&Radiation
|
Compliance to EN55022(CISPR22) ClassB
|
|
Harmonic Current
|
Compliance to EN61000-3-2,-3
|
|
EMS Immunity
|
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA
|
|
OTHERS
|
MTBF (MIL-HDBK-217F)
|
More than 200,000Hrs (25℃, Full load)
|
|
Dimension (L*W*H)
|
101.6×63.5×33mm
|
|
Packing
|
60PCS/CTN, 15.08KGS, 0.06CBM
|
|
Cooling method
|
Cooling by free air convection
|
|
NOTE
|
1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25℃ of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
4. Powerld offer accessories for Din-35 rail bar. Please contact sales staff for details.
|
|