n Features:
Ø Universal AC input/ Full range
Ø High Efficiency, and High reliability
Ø Output protections: OLP/OVP/SCP
Ø Wide operating ambient temperature (-20℃~70℃)
Ø All using 105℃ long life electrolytic capacitors.
Ø 100% full load burn-in test
Ø 3 years warranty
SPECIFICATION
|
MODEL
|
PD-25-S3.3
|
PD-25-S5
|
PD-25-S12
|
PD-25-S15
|
PD-25-S24
|
|
OUTPUT
|
DC Output
|
3.3V
|
5V
|
12V
|
15V
|
24V
|
|
Rated Current
|
6A
|
5A
|
2.1A
|
1.7 A
|
1.1A
|
|
Current Range Note 1
|
0~6A
|
0~5A
|
0~2.1A
|
0~1.7A
|
0~1.1A
|
|
Ripple and Noise
Note 2
|
0~70℃
|
80mV
|
80mV
|
120mV
|
120mV
|
120mV
|
|
-20~0℃
|
240 mV
|
|
Voltage ADJ. Range
|
±10% of rated output voltage
|
|
Voltage Accuracy
|
±2.0%
|
±2.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
|
Line Regulation
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
|
Load Regulation
|
±2.0%
|
±2.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
|
Set-up Time
|
<2.0S (115Vac input, Full load); <1.0S (230Vac input, Full load)
|
|
Hold up Time
|
>14mS(115Vac input, Full load); >30mS(230Vac input, Full load)
|
|
Temperature Coefficient
|
±0.03%/℃
|
|
Overshoot and Undershoot
|
<5.0%
|
|
INPUT
|
Voltage Range
|
88Vac~264Vac
|
|
Frequency Range
|
47Hz~63Hz
|
|
Efficiency ( Typical)
|
70%(115Vacinput)
|
75%(115Vacinput)
|
80%(115Vacinput)
|
81%(115Vacinput)
|
83%(115Vacinput)
|
|
71%(230Vacinput)
|
77%(230Vacinput)
|
82%(230Vacinput)
|
83%(230Vacinput)
|
84%(230Vacinput)
|
|
AC Current (max.)
|
0.7A
|
0.7A
2.5A
|
0.35A
|
0.7A
|
0.7A
|
|
Inrush Current (Typical)
|
20A@115Vac 40A@230Vac Cold start
|
|
Leakage Current
|
Input—output:<0.25mA Input—PG:<0.75mA
|
|
PROTECTION
|
Over Load
|
105%~150% of rated output current, hiccup mode,auto recovery
|
|
Over Voltage
|
105%~150% of rated output voltage, Constant Voltage
|
|
Short Circuit
|
Long-term mode, auto recovery
|
|
ENVIRONMENT
|
Operating amb. Temp. & Hum.
|
-20℃~70℃; 20%~90%RH No condensing((refer to the derating curve)
|
|
Storage Temp. & Hum.
|
-40℃~85℃; 10%~95%RH No condensing
|
|
SAFETY &EMC
Note 3
|
Safety Standards
|
UL60950-1; EN60950-1:2006
|
|
Withstand Voltage
|
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA.
|
|
Isolation Resistance
|
≥100M ohms
|
|
EMI Conduction&Radiation
|
Compliance to EN55022(CISPR22) ClassB
|
|
Harmonic Current
|
Compliance to EN61000-3-2,-3
|
|
EMS Immunity
|
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA
|
|
OTHERS
|
MTBF (MIL-HDBK-217F)
|
More than 100,000Hrs (25℃, Full load)
|
|
Dimension (L*W*H)
|
79×51×28mm
|
|
Packing
|
48PCS/CTN, G.W:10.4kgs
|
|
Cooling method
|
Cooling by free air convection
|
|
NOTE
|
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
|
|