MODEL
|
GPF-U500S12
|
GPF-U500S15
|
GPF-U500S24
|
GPF-U500S27.5
|
GPF-U500S48
|
|
OUTPUT
|
DC Output
|
12V
|
15
|
24V
|
27.5V
|
48V
|
|
Rated Current
|
40A
|
33A
|
20A
|
18A
|
10A
|
|
Current Range Note 1
|
0~40A
|
0~33A
|
0~20A
|
0~18A
|
0~10A
|
|
Ripple and Noise Note 2
|
120mV
|
150mV
|
240mV
|
270mV
|
480mV
|
|
Voltage ADJ. Range
|
11.2V-14.2V
|
13.0V-17.0V
|
21.6V-26.4V
|
22.0V-33.0V
|
40V-50V
|
|
Voltage Accuracy
|
±3.0%
|
±3.0%
|
±3.0%
|
±3.0%
|
±3.0%
|
|
Line Regulation
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
|
Load Regulation
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
|
Set-up Time
|
<4.0S (115Vac input, Full load); <2.0S (230Vac input, Full load)
|
|
Hold up Time
|
>20mS(230Vac input, Full load)
|
|
Temperature Coefficient
|
±0.03%/℃
|
|
Overshoot and Undershoot
|
<5.0%
|
|
INPUT
|
Voltage Range
|
90Vac~264Vac
|
|
Frequency Range
|
47Hz~63Hz
|
|
Power Factor(Typical)
|
PF>0.99/115VAC PF>0.95/230VAC
|
|
Efficiency ( Typical)
|
115Vacinput
|
78%
|
80%
|
81%
|
80%
|
82%
|
|
230Vacinput
|
82%
|
82%
|
86%
|
86%
|
85%
|
|
AC Current (max.)
|
7.3A
2.5A
|
7.5A
|
7.5A
|
7.5A
|
7.3A
|
|
Inrush Current (Typical)
|
<20A@115Vac <40A@230Vac Cold start
|
|
Leakage Current
|
Input—output:<0.25mA Input—PG:<3.5mA
|
|
PROTECTION
|
Over Load
|
105%~140% of rated output current, constant current limiting,auto recover
|
|
Over Voltage
|
115%~150% of rated output voltage, shut down
|
|
Over Temperature
|
95℃+5℃(detect on heatsink of power transistor);shut down,auto recover after the temperature goes down
|
|
Fan ON/OFF Control
|
Output load>55% rating or inside temperature >65℃, FAN ON
|
|
Function
|
Romote ON/OFF Control
|
R.C./G: Short = power on; Open=power off
|
|
ENVIRONMENT
|
Operating amb. Temp. & Hum.
|
-10℃~60℃; 20%~90%RH No condensing(refer to the derating curve)
|
|
Storage Temp. & Hum.
|
-25℃~85℃; 10%~95%RH No condensing
|
|
SAFETY&EMC Note 3
|
Safety Standards
|
UL60950-1; EN60950-1:2006
|
|
Withstand Voltage
|
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA.
|
|
Isolation Resistance
|
≥50M ohms
|
|
EMI Conduction&Radiation
|
Compliance to EN55022 ClassA
|
|
Harmonic Current
|
Compliance to EN61000-3-2,17625.1-2003
|
|
EMS Immunity
|
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level, criteria A
|
|
OTHERS
|
MTBF (MIL-HDBK-217F)
|
More than 100,000Hrs (25℃, Full load)
|
|
Dimension (L*W*H)
|
170×117×94mm
|
|
Packing
|
6PCS/CTN, G.W:13.2kgs
|
|
Cooling method
|
Cooling by forced air (built-in DC fan)
|
|
NOTE
|
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
|