MODEL
|
GZM-U25S5
|
GZM-U25S12
|
GZM-U25S15
|
GZM-U25S24
|
GZM-U25S48
|
|
OUTPUT
|
DC Output
|
5.0V
|
12.0V
|
15.0V
|
24.0V
|
48.0V
|
|
Rated Current
|
5.00A
|
2.10A
|
1.70A
|
1.10A
|
0.55A
|
|
Current Range Note 1
|
0~5.0A
|
0~2.10A
|
0~1.70A
|
0~1.10A
|
0~0.55A
|
|
Ripple and Noise
Note 2
|
0~50℃
|
50mV
|
50mV
|
50mV
|
50mV
|
50mV
|
|
-10℃
|
100mV
|
100mV
|
100mV
|
150mV
|
150 mV
|
|
Voltage ADJ. Range
|
4.5V-5.5V
|
11V-13V
|
13V-16.5V
|
21.5V-25.5V
|
44V-52V
|
|
Voltage Accuracy
|
±2.0%
|
±2.0%
|
±2.0%
|
±2.0%
|
±2.0%
|
|
Line Regulation
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
|
Load Regulation
|
±2.0%
|
±2.0%
|
±2.0%
|
±2.0%
|
±2.0%
|
|
Set-up Time
|
<3.0S (120Vac input, Full load); <1.5S (220Vac input, Full load)
|
|
Hold up Time
|
>10mS(120Vac input, Full load); >20mS(220Vac input, Full load)
|
|
Temperature Coefficient
|
±0.03%/℃
|
|
Overshoot and Undershoot
|
<5.0%
|
|
INPUT
|
Voltage Range
|
90Vac~264Vac
|
|
Frequency Range
|
47Hz--63Hz
|
|
Efficiency ( Typical)
|
76%
|
78%
|
80%
|
82%
|
84%
|
|
AC Current (max.)
|
0.7A
|
|
Inrush Current (Typical)
|
20A@120Vac 40A@220Vac Cold start
|
|
Leakage Current
|
Primary-Secondary: <0.25mA Primary-Gvround: <3.5mA
|
|
PROTECTION
|
Over Power
|
105%~150% of rated output current, auto recovery
|
|
Over Current
|
105%~150% of rated output current, auto recovery
|
|
Over Voltage
|
105%~150% of rated output voltage, auto recovery
|
|
Shorted Circuit
|
Long-term mode, auto recovery
|
|
ENVIRONMENT
|
Operating amb. Temp. & Hum.
|
-10℃~50℃; 20%~90%RH No condensing
|
|
Storage Temp. & Hum.
|
-40℃~85℃; 10%~95%RH No condensing
|
|
SAFETY &EMC
(Note 3)
|
Safety Standards
|
GB4943-2001; EN60950-1:2006
|
|
Withstand Voltage
|
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVdc;≤10mA.
|
|
Isolation Resistance
|
≥100M ohms
|
|
EMI Conduction&Radiation
|
Compliance to EN55022(CISPR22)ClassB
|
|
EMS Immunity
|
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA
|
|
OTHERS
|
MTBF (MIL-HDBK-217F)
|
More than 100,000Hrs (25℃, Full load)
|
|
Dimension (L*W*H)
|
143×59×38mm
|
|
Cooling method
|
Cooling by free air convection
|
|
NOTE
|
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
|