Congratulations to the success of Powerld Web site revision
Product Details  
PSF-125

Features:

Ø  Universal AC input/ Full range

Ø  Built-in active PFC function,PF>0.95

Ø  High power density,High effiency and reliability

Ø  Output protections: OLP/OVP/SCP

Ø  Wide operating ambient temperature (-20~70)

Ø  Build-in remote sense function

Ø  All using 105 long life electrolytic capacitors.

Ø  100% full load burn-in test

Ø  3 years warranty

SPECIFICATION                                                      

MODEL

PSF-125-5

GZM-H25S8.5

PSF-125-12

 

 

GZM-H25S12II

PSF-125-15

 

PSF-125-24

 

PSF-125-48

OUTPUT

DC Output

5V

8.5V

12V

12V

15V

24V

48V

Rated Current

20A

3A

10.5A

2 A

8.4A

5.2A

2.6A

Current Range    

0~20A

0~3A

0~10.5A

0~2A

0~8.4A

0~5.2A

0~2.6A

Ripple and Noise  Note 2

<100mV

85mV

<100mV

120mV

<100mV

 

<100mV

 

<150 mV

Voltage ADJ.  Range

4.5~5.7V

10.6~13.4V

12.9~17.0V

24.7~27.0V

43.0~53.7V

Voltage Accuracy

±2.0%

±3.0%

±2.0%

±5.0%

±2.0%

±2.0%

±2.0%

Line Regulation

±0.5%

±0.5%

±0.5%

±1.0%

±0.5%

±0.5%

±0.5%

Load Regulation

±2.0%

±2.0%

±2.0%

±1.0%

±2.0%

±2.0%

±2.0%

Set-up Time

<1.2S (230Vac input, Full load)    <2.5S (115Vac input, Full load)

Hold up Time

>20mS(115/230Vac input, Full load)

Temperature Coefficient

±0.03%/℃

Overshootand Undershoot

<5.0%

INPUT

Voltage Range  

90Vac~264Vac,127Vdc~370Vdc

Frequency Range

47Hz--63Hz

Power Factor(Typical)

PF0.98@115VAC    PF0.95@230VAC

Efficiency ( Typical)

115Vac input

83%

85%

85%

86%

86%

230Vac input

85%

87%

87%

88%

88%

AC Current (max.)

<1.5A

0.5A

2.5A

1.5A

0.3A

1.5A

1.5A

1.5A

1.5A

Inrush Current (Typical)

<60A@230Vac   <30A@115Vac   Cold start

Leakage Current

<3.5mA

PROTECTION

Over Current

105%~150% of rated output current, hiccup mode, auto recovery

Over Voltage

120%~150% of rated output voltage,hiccup mode

Short Circuit

Auto recovery

ENVIRONMENT

OperatingambTemp& Hum

-20℃~70℃;  20%~90%RH  No condensing (refer to the derating curve)

Storage Temp. & Hum.

-40℃~85℃;  10%~95%RH  No condensing

SAFETY &EMC   

Note 3

Safety Standards

UL60950-1; EN60950-12006

Withstand Voltage

Primary-Secondary:3.0KVac;10mA .Primary-PG:1.5KVac;10mA .Secondary-PG:0.5KVDC;≤10mA .

Isolation Resistance

>100M ohms

EMI Conduction&Radiation

Compliance to EN55022(CISPR22)ClassB

Harmonic Current

Compliance to EN61000-3-2,-3

EMS Immunity

Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA

OTHERS

MTBF (MIL-HDBK-217F)

More than 100,000Hrs (25℃, Full load)

Dimension  (L*W*H)

127×76×30.5mm

Packing

21PCS/CTN, 8.46KGS, 0.015CBM

Cooling method

Cooling by free air convection

 

NOTE

1.     All parameters NOT specially mentioned are measured at 230Vac rated input, rated load and 25℃ of ambient temperature.

2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.

3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.