n Features:
Ø Universal AC input/ Full range
Ø High Efficiency, low power consumption
Ø Output protections: SCP/OVP/ OLP
Ø Wide operating ambient temperature (-25℃~70℃)
Ø All using 105℃ long life electrolytic capacitors.
Ø 100% full load burn-in test
Ø 3 year warranty
SPECIFICATION
|
MODEL
|
PS-60-5
|
PS-60-12
|
PS-60-15
|
PS-60-24
|
PS-60-48
|
|
OUTPUT
|
DC Output
|
5.0V
|
12.0V
|
15.0V
|
24.0V
|
48.0V
|
|
Rated Current
|
8.0A
|
4.5A
|
3.6A
|
2.5 A
|
1.25A
|
|
Ripple and Noise
Note 2
|
0~70℃
|
<50mV
|
<120mV
|
<120mV
|
<120mV
|
<240mV
|
|
-25℃~0℃
|
<200mV
|
<300mV
|
<300mV
|
<300mV
|
<360mV
|
|
Voltage ADJ. Range
|
4.5~5.5V
|
11.2~13.4V
|
13.8~16.5V
|
22.2~27.9V
|
45.0~53.2V
|
|
Voltage Accuracy
|
±3.0%
|
|
Line Regulation
|
±0.5%
|
|
Load Regulation
|
±2.0%
|
|
Set-up Time
|
≤1.0S (230Vac input, Full load)
|
|
Hold up Time
|
≥20mS(230Vac input, Full load)
|
|
Temperature Coefficient
|
±0.03%/℃
|
|
Overshoot and Undershoot
|
<5.0%
|
|
INPUT
|
Voltage Range Note 3
|
90Vac~264Vac, 127Vdc~370Vdc
|
|
Frequency Range
|
47Hz-63Hz
|
|
Efficiency ( Typical)
|
115Vac input
|
79%
|
83%
|
84%
|
87%
|
85%
|
|
230Vac input
|
82%
|
85%
|
85%
|
87%
|
88%
|
|
AC Current (max.)
|
<1.5A
|
|
Inrush Current (Typical)
|
<30A@120Vac <60A@230Vac Cold start
|
|
Leakage Current
|
<0.25mA
|
|
PROTECTION
|
Over Load
|
105%~180% of rated output current, hiccup mode,auto recovery
|
|
Over Voltage
|
110%~150% of rated output voltage, Constant voltage,
|
|
Shorted Circuit
|
Long-term mode, auto recovery
|
|
ENVIRONMENT
|
Operating amb. Temp. & Hum.
|
-25℃~70℃; 20%~90%RH No condensing (refer to the derating curve)
|
|
Storage Temp. & Hum.
|
-40℃~85℃; 10%~95%RH No condensing
|
|
SAFETY &EMC
(Note 4)
|
Safety Standards
|
UL60950-1; EN60950-1:2006
|
|
Withstand Voltage
|
Primary-Secondary:3.0KVac; ≤10mA .
|
|
Isolation Resistance
|
≥100M ohms
|
|
EMI Conduction&Radiation
|
Compliance to EN55022(CISPR22)ClassB
|
|
Harmonic Current
|
Compliance to EN61000-3-2,-3
|
|
EMS Immunity
|
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA
|
|
OTHERS
|
MTBF (MIL-HDBK-217F)
|
More than 200,000Hrs (25℃, Full load)
|
|
Dimension (L*W*H)
|
101.6×50.8×30mm
|
|
Packing
|
60PCS/CTN, 12KGS, 0.024CBM
|
|
Cooling method
|
Cooling by free air convection
|
|
NOTE
|
1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25℃ of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor.
3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
|
|