Congratulations to the success of Powerld Web site revision
Product Details  
PD-50

n  Features:

Ø  No Load power consumption<0.5W

Ø  Withstand 300VA surge input for 5 sec.

Ø  High Efficiency, High reliability and long life

Ø  Output protections: OLP/OVP/SCP

Ø  Wide operating ambient temperature (-20~70)

Ø  All using 105 long life electrolytic capacitors.

Ø  100% full load burn-in test

Ø  Terminal block with plastic cover

Ø  3 years warranty     

SPECIFICATION                                             

MODEL

PD-50-5

PD-50-12

PD-50-15

PD-50-24

PD-50-48

OUTPUT

DC Output

5V

12V

15V

24V

48V

Rated Current

8A

4.2A

3.3A

2.2A

1.1A

Current Range     

0~8A

0~4.2A

0~3.3A

0~2.2A

0~1.1A

Ripple and Noise   (-20~70)Note 2

<80mV

<120mV

<120mV

<200mV

<200 mV

Voltage ADJ.  Range

±10% of rated output voltage

Voltage Accuracy

±3.0%

±3.0%

±3.0%

±3.0%

±3.0%

Line Regulation

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load Regulation

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

Set-up Time

2.0S (115Vac input, Full load); 1.5S (230Vac input, Full load)

Hold up Time

20mS(115Vac input, Full load); 50mS(230Vac input, Full load)

Temperature Coefficient

±0.03%/℃

Overshoot and Undershoot

<5.0%

INPUT

Voltage Range  

90Vac~264Vac127~370Vdc

Frequency Range

47Hz~63Hz

Efficiency ( Typical)

115Vacinput

79%

84%

85%

86%

88%

230Vacinput

80%

85%

86%

87%

89%

AC Current (max.)

<1.3A

Inrush Current (Typical)

<20A@115Vac    <40A@230Vac      Cold start

Leakage Current

Input—output:<0.25mA     Input—PG:<0.75mA

PROTECTION

Over Load

105%~150% of rated output current, constant power

Over Voltage

105%~150% of rated output voltage, Constant Voltage

Short Circuit

Long-term mode, auto recovery

ENVIRONMENT

Operating amb. Temp. & Hum.

-20℃~70℃;  20%~90%RH  No condensing((refer to the derating curve)

Storage Temp. & Hum.

-40℃~85℃;  10%~95%RH  No condensing

SAFETY &EMC

Note 3

Safety Standards

UL60950-1; EN60950-12006

Withstand Voltage

Primary-Secondary:3.0KVac; 10mA .Primary-PG:1.5KVac; 10mA. Secondary-PG:0.5KVDC;10mA.

Isolation Resistance

100M ohms

EMI Conduction&Radiation

Compliance to EN55022(CISPR22) ClassB

Harmonic Current

Compliance to EN61000-3-2,-3

EMS Immunity

Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA

OTHERS

MTBF (MIL-HDBK-217F)

More than 200,000Hrs (25℃, Full load)

Dimension  (L*W*H)

99×82×38mm

Packing

40PCS/CTN, 13KGS, 0.043CBM

Cooling method

Cooling by free air convection

 

NOTE

1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.

2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.

3.        The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.

4.        Powerld offer accessories for Din-35 rail bar. Please contact sales staff for details.