MODEL
|
VAT-H200-5
|
VAT-H200-12
|
VAT-H200-24
|
|
OUTPUT
|
DC Output
|
5V
|
12V
|
24V
|
|
Rated Current
|
40A
|
16.7A
|
8.3A
|
|
Current Range Note 1
|
0-40A
|
0~16.7A
|
0~8.3A
|
|
Ripple and Noise
Note 2
|
0~65℃
|
200mV
|
120mV
|
120mV
|
|
Voltage ADJ. Range
|
±10% of rated output voltage
|
|
Voltage Accuracy
|
±2.0%
|
±1.0%
|
±1.0%
|
|
Line Regulation
|
±0.5%
|
±0.5%
|
±0.5%
|
|
Load Regulation
|
±2.0%
|
±1.0%
|
±1.0%
|
|
Set-up Time
|
<2.5S (220Vac input, Full load)
|
|
Hold up Time
|
>20mS(220Vac input, Full load)
|
|
Temperature Coefficient
|
±0.03%/℃
|
|
Overshoot and Undershoot
|
<5.0%
|
|
INPUT
|
Voltage Range
|
176Vac~264Vac
|
|
Frequency Range
|
47Hz~63Hz
|
|
Efficiency ( Typical)
|
81%(220Vac input)
|
85%(220Vac input)
|
87%(220Vac input)
|
|
AC Current (max.)
|
2.5A
|
|
Inrush Current (Typical)
|
50A@220Vac Cold start
|
|
Leakage Current
|
Input—output:<0.25mA Input—PG:<0.5mA
|
|
PROTECTION
|
Over Power
|
105%~150% of rated output power, auto recovery
|
|
Over Current
|
105%~150% of rated output current, auto recovery
|
|
Over Voltage
|
105%~150% of rated output voltage, auto recovery
|
|
Shorted Circuit
|
Long-term mode, auto recovery
|
|
ENVIRONMENT
|
Operating amb. Temp. & Hum.
|
-40℃~65℃; 20%~90%RH No condensing
|
|
Storage Temp. & Hum.
|
-40℃~85℃; 10%~95%RH No condensing
|
|
SAFETY &EMC
Note 3
|
Safety Standards
|
GB4943-2001; EN60950-1:2006
|
|
Withstand Voltage
|
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA.
|
|
Isolation Resistance
|
≥100M ohms
|
|
EMI Conduction&Radiation
|
/
|
|
Harmonic Current
|
/
|
|
EMS Immunity
|
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA
|
|
OTHERS
|
MTBF (MIL-HDBK-217F)
|
More than 100,000Hrs (25℃, Full load)
|
|
Dimension (L*W*H)
|
199×99×50mm
|
|
Packing
|
12pcs/carton GW:9.2KGS
|
|
Cooling method
|
Cooling by free air convection
|
|
NOTE
|
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor.
3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
4. If you need fixture A or fixture B for install purpose,please contact our sales.
|